Laserfiche WebLink
' � aos <br /> FORM R405-2014 <br />� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 sf ADS Builder Name: Lennar Homes <br /> street: 36124 Stable Wilk Avenue Permit Office: <br /> City,State,Zip: ,FL, Permit Number <br /> Owner Lennar Homes Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1378.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftx <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1936 b CathedraUSingle Assembly(Vented) R=30.0 342.00 ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11 Ducts R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftZ <br /> SHGC� SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC� SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ft2 <br /> SHGC� SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A - ftZ a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC� 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> B. Floor Types (1936.0 sqft.) Insulation Area EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/FloorArea: 0.081 Total Proposed Modified Loads: 58.15 PASS <br /> Total Baseline Loads: 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'C�S7''�QZ, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �v�� ,, "'`_�. �C,��, , <br /> Code. calculation indicates compliance �'�ul,�'`' =;$r:�,�� . <br /> �" with the Florida Energy Code. F+" trr�t�����;:'��,� O <br /> PREPARED BY� �GtVe f�GG��'(GVl Before construction is completed � �-;; � '��.�� �� '° � � <br /> cd (i+ �:•. ... C7 <br /> DATE: this building will be inspected for �,- �;,�; . �.' . <br /> compliance with Section 553.908 * $ �. <br /> I hereby certify that this building,as desig ed, is in compliance Florida Statutes. .r;�, , � ' � ��. . <br /> with the Florida Energy Code. COD W�'�F`� <br /> OWNER/AGENT: � BUILDING OFFICIAL. <br /> DA�E: DATE: ' � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />