Laserfiche WebLink
'i' y <br /> FORM R405-2014 <br /> F.LORIDA ENERGY EFFICIENCY� CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2421 sf ADS drawn Builder Name: Lennar Homes <br /> - street: 6599 Paden Wheel Street Permit Office. Cl of Zephyrhills <br /> City,State,Zip: , FL, Permit Number• %��5 <br /> Owner� �ennar Homes .lurisdiction: 611600 <br /> Design Location. FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ft2 <br /> 3. Number of units, if multiple family 1 c.N/A R= ft: <br /> 4. Number of Bedrooms 4 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area <br /> a. Under Attic(Vented) R=30.0 1901.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(230.7 sqft.) Description Area a.Sup•Attic, Ret:dining rm,AH:laundry 6 483 <br /> a. U-Factor• Dbl, U=0.54 140.00 ftz <br /> SHGC• SHGC=0.31 <br /> b. U-Factor� Dbl, U=0.58 64 00 ft2 12.Cooling systems � kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl, U=0.56 26.67 ftz <br /> SHGC• SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a. Electric Heat Pump 32.8 HSPF.8.70 <br /> SHGC� <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC� 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2420.2 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.095 <br /> Total Proposed Modified Loads 71.47 pASS <br /> Total Baseline Loads: 73.07 <br /> I hereby certify that the plans and specifications covered by Review of the plans and , ���:$T.q�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��., � �'�p�, <br /> Code. calculation indicates compliance �'�,;�,''� d;.`,.�,`j�«s+�,,. <br /> with the Florida Ener Code. F^+ �rrrr��%, .j�::�:�^'',�� <br /> /. 9Y r�� �' ��,1, �� O <br /> PREPARED BY: _ �G�V� ���'IGVI Before construction is completed ri ��,� � `'"" � <br /> DATE: this building will be inspected for � �`"f����w "", � <br /> compliance with Section 553.908 * � • ,� <br /> I hereb certi that this buildin as desi ned, i in com liance Florida Statutes. fi,: <br /> Y fY 9� 9 P `� �S. <br /> with the Florida Energy Code. '�O?j.�,y�.T��-� <br /> OWNER/AGENT: BUILDIN OFFICIAL: <br /> DATE: � / DATE: ' � <br /> - Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 8:35 AM EnergyGaugeO USA-FlaRes2014 Section R405 4.1 Compliant SoHware Page 1 of 6 <br />