17-18305
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2017 2:08:35 PM
Creation date
12/18/2017 2:08:33 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18305
Building Department - Name
LENNAR HOMES LLC
Address
6599 PADEN SHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method , <br /> Project Name: 2421 sf ADS drawn Builder Name: Lennar Homes <br /> street: 6599 Paden Wheel Street Permit Office. City of Zephyrhills <br /> City,State,Zip: , FL, Permit Number• <br /> Owner� �ennar Homes .lurisdiction. 611600 <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.0 1874.90 ftZ <br /> b. Frame-Wood,Adjacent R=11.0 469.69 ftz <br /> 3. Number of units, if multiple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421 0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1901.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2421 b.Cathedral/Single Assembly(Vented) R=30.0 520.00 ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11 Ducts R ftz <br /> 7. Windows(230.7 sqft.) Description Area a.Sup�Attic,Ret:dining rm,AH:laundry 6 483 <br /> a. U-Factor Dbl, U=0 54 140.00 ft2 <br /> SHGC� SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.32 a.Central Unit 34.8 SEER.15.20 <br /> c. U-Factor Dbl, U=0.56 26.67 ftz <br /> SHGC: SHGC=0.28 13 Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC• <br /> Area Weighted Average Overhang Depth. 4.283 ft. <br /> Area Weighted Average SHGC• 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2420.2 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 b. Conservation features <br /> b.N/A R= ftz None <br /> c. N/A R= ft2 15.Credits Pstat <br />� Total Proposed Modified Loads: 71.47 pASS <br /> Glass/Floor Area: 0.095 <br /> Total Baseline Loads� 73.07 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'f���T.q�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��. =-=_''�p�,, <br /> Code. calculation indicates compliance �'�ri,,l�`''� '�z=����` Ys+ <br /> with the Florida Energy Code. F+ NtPtG�'r�,%�`;��'�°;.�`��,��O <br /> /"/ �. ;;�, �.,, .,... � <br /> PREPARED BY: �aV� �GUI�� Before construction is completed u�3" ,,, <br /> DATE: this building will be inspected for � � i,,����� ,� <br /> compliance with Section 553.908 * •�''• e: <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ✓,�,� , . ��h � <br /> with the Florida Energy Code. � �I?�!T`�' <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 8:35 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.