Laserfiche WebLink
Building Analysis Job: 1450sf <br /> i Date: 17J30/2016 <br /> En tire Ho us e By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> , <br /> ' � - s • <br /> For: Lennar Homes <br /> , - • s � s <br /> Location: Indoor: Heating Cooling <br /> Tampa InternationalAP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 <br /> Dry bulb (°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb (°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> . <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 5.6 6012 27.5 <br /> Glazing 30.2 3422 15.6 I <br /> Doors 23.5 480 2.2 <br /> Ceilings 1.3 1833 8.4 <br /> Floors 3.8 5544 25.3 <br /> Infiltration 2.3 2746 12.5 <br /> D ucts 1851 8.5 <br /> Piping 0 0 <br /> Humidification 0 0 ""' <br /> Ventilation 0 0 �, <br /> Adjustments 0 �M <br /> Total 21888 100.0 <br /> e • . <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 2.8 2991 15.4 '" <br /> Glazing 47.8 5420 27 8 ���. <br /> Doors 18.4 376 1.9 <br /> Ceilings 1.7 2534 13.0 f <br /> Floors 0 0 0 / <br /> Infiltration 0.5 589 3.0 <br /> D ucts 2136 11.0 . <br /> Ventilation 0 0 �az� <br /> Internal gains 5435 27.9 �„ <br /> Blower 0 0 <br /> Adjustments 0 „„m„�� <br /> Total 19481 100.0 �., <br /> Latent Cooling Load= 2499 Btuh <br /> Overall U-value= 0.107 Btuh/ftz-°F <br /> Data entries checked. <br /> -�- wrightsoftm 2016-Dec-30 10:38:03 <br /> �. Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �� H:\LENNAR LOADS\1450 sf ADS 2ton.rup Calc=MJ8 Front Door faces: S <br />