Laserfiche WebLink
Pro ect Summa Job: 1450 sf <br /> J � Date: 12/3012016 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> " s - s • <br /> For: Lennar Homes <br /> Notes: <br /> � - • e s <br /> Weather� Tampa InternationalAP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 9� °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range � <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 20036 Btuh Structure 17345 Btuh <br /> Ducts 1851 Btuh Ducts 2136 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 21888 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19481 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2122 Btuh <br /> Ducts 377 Btuh <br /> Heating Cooling Central vent (0 cfm) 0 Btuh <br /> Area(ftZ) 1461 1461 Equipment latent load 2499 Btuh <br /> Volume(ft') 12328 12328 <br /> Air changes/hour 0.31 0.16 Equipment total load 21980 Btuh <br /> Equiv.AVF (cfm) 64 33 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024230-18 Cond 14HPX-024-230-18 <br /> AHRI ref 5186808 Coil CBX27UH-024-230"++TDR <br /> AHRI ref 5186808 <br /> Efficiency 9 HSPF Efficiency 13.7 EER, 16.2 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.041 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2016-Dec-30 10:38:03 <br /> �, '�'�' wrightsoftw Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\1450 sf ADS 2ton.rup Calc=MJ8 Front Door faces: S <br />