Laserfiche WebLink
Manual S Compliance Report Job: 1450sf <br /> Date: 12I30/2016 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> s � - • s <br /> For: Lennar Homes <br /> s e e � � <br /> Design Conditions <br /> Outdoor design DB• 91.3°F Sensible gain: 19481 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 2499 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 21980 Btuh <br /> Indoor RH: 50% Estimated airflow� 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 110% of load <br /> Latent capacity 3780 Btuh 151% of load <br /> Total capacity• 25200 Btuh 115% of load SHR: 85% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss: 21888 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions ' <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 100% of load Capacity balance: 38 °F <br /> Supplemental heat required: 88 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 800 cfm <br /> Output capacity. 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> „ wri htsoft� 2016-Dec-3010:36:03 <br /> �,�, g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\1450 sf ADS 2ton.rup Calc=MJB Front Door faces: S <br />