Laserfiche WebLink
1 <br /> � <br /> I <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali Elevati n D Builder Name: DRH Exprgss H mes /p <br /> Street: �13�'s�b��� I��21�,�L Permit Office: (��6��iL{/�t,�l-�1 <br /> City,State,Zip: Zephyrhills,FL,Z`]��.'I Permit Number: `� � <br /> Owner: �rJ � Jurisdiction: �!�(pdb <br /> Design Location: FL,Tampa ���/ County:: Pasco(Florida Climate Zone 2) <br /> �� ! � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b. Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A z - <br /> R= ft <br /> 4. Number of Bedraoms 4 d.N/A R_ ft2 <br /> � 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case. No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> � 11. Ducts R ft2 <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1828.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= n2 15.Credits Pstat <br /> Glass/Floor Area: 0.091 <br /> Total Proposed Modified Loads: 60.65 pASS <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��TH�ST,�T� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �� ���f '' � � p <br /> Code. calculation indicates compliance ,�w'�,,, `� �='',.� � <br /> with the Florida Energy Code. ti rr,r,r�''�.�-:;,=�'�°':��`���„ O <br /> PREPARED BY: 1.'N4_�.,�.�.. Before construction is completed � ; ` � <br /> DATE: II-7-16 this building will be inspected for � "'1:���3 ,3� <br /> f,s�: <br /> compliance with Section 553.908 * �� n � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ,� y,t <br /> with the Florida Energy Code. GOD��� <br /> OWNER/AGEN . BUILDING OFFICIAL: <br /> DATE: DATE: `�� '� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler closure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage�n requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gln for whole house. <br /> 11/7/2016 10:14 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />