My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18368
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18368
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 9:47:51 AM
Creation date
12/19/2017 9:47:49 AM
Metadata
Fields
Template:
Building Department
Company Name
SIVLERADO
Building Department - Doc Type
Permit
Permit #
17-18368
Building Department - Name
D R HORTON INC
Address
36137 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Pertormance Method <br /> Project Name: Cali Elevation D � Builder Name: DRH Express Homes <br /> Street: �13�'��b I��` I k.�e.1�,1�L Permit Office: <br /> City,State,Zip: Zephyrhills,FL��.'I Permit Number: <br /> Owner: �5 �/ Jurisdiction: <br /> Design Location: FL,Tampa 1�// County:: Pasco(Florida Climate Zone 2) <br /> !� ( <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R_ ftz <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ft�) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ft�) 0 � c.N/A R= ftz <br /> 11. Ducts R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1828.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation , R=0.0 1528.00 ftz b. Conservation features <br /> b.WA R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.091 <br /> Total Proposed Modified Loads: 60.65 pASS <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�'�STAT� <br /> this calculation are in compliance with the Florida Energy specifications covered by this -� �� p <br /> Code. calculation indicates compliance ��i'�„��'`� =�`���.� �s <br /> with the Florida Energy Code. ti rnJ,�:���-;';Y::�:�;•�;,`�p <br /> PREPARED BY: �'M11�-�� Before construction is completed r� ''' "''-' � <br /> DATE: II-7-IG this building will be inspected for � --=�-,�� - ,� <br />, compliance with Section 553.908 * ° � <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. ,S <br /> with the Florida Energy Code. �G'G�D ��� <br /> OWNER/AGEN . BUILDING OFFICIAL: ���� ' <br /> DATE: DATE: -��7- � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming.duct leakage to outdoors, <br /> � tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 G1n for whole house. <br /> 11/7/2016 10:14 AM EnergyGauge(�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.