Laserfiche WebLink
� � . <br /> FORM R405-2014 ' <br /> �FLORIDA ENERC;Y EFFICIENCY CODE FOR BUILDING CO�ISTRUCTION I <br /> Florida Department of Business and Professional Regulation - Residential Performance Method � <br /> Pro'ect Name: Cali Elevation ,�I,�( k Builder Name: DR Ex re s Hom s l <br /> Street: �IG�I� ��I I `���� Permit Office: �`� P �7�c/� <br /> �1 KS ���Y <br /> City,State,Zip: Zephyrhills,FL,'l�f/J 1 � Permit Number: ��3�U� <br /> �k7�r l <br /> Owner: Jurisdictian: �p <br /> Design Location: FL,Tampa Zt / County:: Pasco�Florida Climate Zone 2) <br /> ( <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4, Number of Bedrooms 4 d.N/A R= ftz <br /> 10. Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz <br />� 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11. Ducts R ftz <br /> 7 Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: � N/A ftz � <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 , <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br />, Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8, Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Ed e Insulation R=0.0 1828.00 ft2 ' EF:0.950 <br /> 9 b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 60.72 � p �� <br /> Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 �`��� <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��T�E�T�g� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ��� _�` p� <br /> Code. calculation indicates compliance � �,,,�o'':� =_�,.� <br /> with the Florida Energy Code. ti rrrrr:�K'��.�;:�i:"•°:���,ti�O <br /> P R E P A R E D B Y: �'►'�'4-�� B e f o r e c o n s t r u c t i o n i s c o m p l e t e d c� •-� '' ` � <br /> s�. �_.,, v . <br /> DATE: II-7-16 this building will be inspected for � I;;;�`� - ,3, � <br /> compliance with Section 553.908 * �` ° � <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. .� �� <br /> with the Florida Energy Code. �QD yyE�� <br /> OWNER/AGENT: BUILDING OFFICIAL: �� I <br /> DATE: U 'z�- , DATE: �'�'--� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as I <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.'1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gln for whole house. <br /> 1 1/7/201 6 9:32 AM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />