My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18370
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18370
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 9:48:51 AM
Creation date
12/19/2017 9:48:49 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18370
Building Department - Name
D R HORTON INC
Address
36185 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ' , <br /> � FORM R405-2014 <br /> �FLO�ID� EtVEI�GV EFFICIENCY CODE FOi� �CJIL�IIVG COMSTRUCTI0�9 <br /> Florida Department of Business and Professional Regulation - Residential Pertormance Method <br /> Project Name: �iE�evatio��(� I �,I �/ �� Buiider Name: DRH Express Homes <br /> Street: � t �`�'��Z � Permit Office: <br /> �-l..Q �J <br /> City,State,Zip: Zephyrhilis, FL,'l�C,I I � Permit Number: <br /> Owner: w`���� � Jurisdiction: <br /> Design Location: FL,Tampa ZI 1 County:: Pasco(Florida Climate Zone 2) <br /> � <br /> 1. New construction or e�risting New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or muitiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d•N�A R= {�z <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> _ 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 h.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= {�z <br /> 11. Ducts R ftz <br /> 7. Windows(166.5 sqft.) Descripfion Area a.Sup:Attic, Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> 6. U-Factor: Dbl, U=0.55 40.00 ftz 12. Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> � c. U-Factor: N/A ftz <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6. HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: . 0.317 14. Hot water systems <br /> 8. Floor Types (1828.0 sqft.) insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz EF:0.950 <br /> b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits <br /> Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.72 � A �� <br /> Total Baseline Loads: 61.25 f1 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O��HE STA?,� <br /> this calculation are in compfiance with the Florida Energy specifications covered by this ��' = � p <br /> Code. calculation indicates compfiance �w'�,;�`"' =';`,o� <br /> v� .. ���,5ti`�� <br /> with the Florida Energy Code. h �h�,; ���,,:;�;�.•,;,., <br /> PREPARED BY: �'N1�-�� Before construction is completed � - <br /> DATE: II-7-16 this building will be inspected for � �j��� :-� ,�,d <br /> compliance with Secfion 553_908 * s � <br /> I hereby certify that this building, as designed, is in compfiance Florida Statutes. ,�� �,t <br /> with the Florida Energy Code. � '�'(�D��'� <br /> , <br /> OWNER/AGENT: , � BUILDING OFFICIAL: <br /> D.ATE: ��� � � ,�_, DATE: �.�- <br /> - , . <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4Q2.4.1.1 and an envelope leakage <br /> test report in accordance with R4Q2:4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Secfion 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 1 117/201 6 9:32 AM EnergyGaugeC�USA-FlaRes2014 Section R4Q5.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.