Laserfiche WebLink
e � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Pro ect Name: Aria Elevatio Dc 1 ��i ' I Builder Name: DRH Ex ress Homes / / <br /> Street: � ��'�J�I��-/�I� v��� Permit Office: �`�U�-�j�l'1tr�Os' <br /> City,State,Zip: Zephyrhills,FL��(,�( � / Permit Number: (� � <br /> Owner: �V Jurisdiction: 6 t[bOt� <br /> Design Location: FL,Tampa 22/ County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ftz <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number af Bedrooms 3 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area Z <br />, a.Under Attic(Vented) R=30.0 1672.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11 Ducts R ftz <br /> 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 <br /> a. U-Factor: Dbl,U=0.34 142.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.985 ft. � <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 49.02 pASS <br /> Glass/Floor Area: 0.109 <br /> Total Baseline Loads: 57.14 <br /> I hereby certify that the plans and specifications covered by Review of the plans and D�THE STq� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ,��, '�_ ;� O�, <br /> Code. calculation indicates compliance r,, �i,, '' w;,��,�` M' <br /> with the Florida Energy Code. N rrr„�:., ���,�:°;;;��;•�"„�O <br /> ..,,.�. . <br /> PREPARED BY: LMk.�.M:,.. Before construction is completed � <br /> DATE: II-7-16 this building will be inspected for � �'�I`����,�`" ,� <br /> compliance with Section 553.908 * t:' ° ,� <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ✓ ��� <br /> with the Florida Energy Code. �D{ry�i'� <br /> OWNER/AGEN . BUILDING _ F.1�,1� ' <br /> DATE: DATE: G� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. �I <br /> 11/7/2016 9:38 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />