Laserfiche WebLink
, � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Aria Elevatio D 1 ��� �/ ��� Builder Name: DRH Express Homes <br /> Street: � ��"���I�w�I �� C Permit Office: <br /> City,State,Zip: Zephyrhills, FL��(,1' � / Permit Number• <br /> Owner: �V Jurisdiction: <br /> Design Location: FL,Tampa Z2/ County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(16582 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family 'a.Concrete Block-Int Insul,Exterior R=4.1 1372.20.ftz <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R_ ftZ <br /> 10.Ceiling Types (1672.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1672 b.N/A R= ftz <br />� Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 <br /> a. U-Factor: Dbl,U=0.34 142.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.985 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1672.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 49.02 ' pASS <br /> Glass/Floor Area: 0.109 Total Baseline Loads: 57.14 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��THE ST,q� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��y =__ � p = <br /> Code. calculafion indicates compliance ��'�'�„°''� ';;�,� �,+ <br /> ,� ,o � <br /> with the Florida Energy Code. ti rx�r;.,�•-;:;;f:,''��;;��„ p� <br /> PREPARED BY: �'�.�•� Before construction is completed � ' ., <br /> DATE: II-7-16 this building will be inspected for � ���j����- . �,,d <br /> compliance with Section 553.908 * " ° ,� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,t� ��,5 <br /> with the Florida Energy Code. �� <br /> OWNER/AGEN . BUILDING O CIAL: <br /> DATE: DATE: ���f'� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist_in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 11l7/2016 9:38 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />