Laserfiche WebLink
tFORM�R405-2014 <br /> . ' CEILING <br /> # Ceiling Type Space R-Value Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) 2nd Fldor 30 1998 ftz 0.1 Wood <br /> 2 Knee Wall(Vented) 2nd Floor 30 132 ftz 0.11 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 N=>SW Exterior Concrete Block-Int Insul 1st Floor 4.1 21 2 9 4 197.6 ftz 0 0 0.6 0 <br /> 2 S=>NE Exterior Concrete Block-Int Insul 1st Floor 4 1 50 0 9 4 466.7 ft2 0 0 0.6 0 <br /> 3 E=>NW Exterior Concrete Block-Int Insul 1st Floor 4 1 40 4 9 4 376.4 ftz 0 0 0.6 0 <br /> 4 W=>SE Exterior Concrete Block-Int Insul 1st Floor 4.1 40 4 9 4 376.4 ftz 0 0.6 0 <br /> _ 5 N=>SW Garage Frame-Wood 1 st Floor 11 21 4 9 4 199.1 ftZ 0.23 0.01 0 <br /> 6 N=>SW Exterior Frame-Wood 2nd Floor 11 50 8 400 0 ftz 0.23 0.6 0 <br /> 7 S=>NE Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ftz 0.23 0.6 0 <br /> 8 E=>NW Exterior Frame-Wood 2nd Floor 11 58 8 8 469.3 ftZ 0.23 0.6 0 <br /> 9 W=>SE Exterior Frame-Wood 2nd Floor 11 58 8 8 469.3 ftZ 0.23 0 6 0 <br /> 10 N=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 6 9 4 70.0 ftz 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>SW Insulated 1st Floor None .2 3 6 8 20 ftz <br /> 2 N=>SW Wood 1st Floor None 4 2 8 6 8 17.8 ftZ <br /> WINDOWS <br /> Orientation shown is the entered orientation(_>)changed to Worst Case. <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftz 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 <br /> 2 N=>SW 1 Metal Low-E Double Yes 0.56 0.28 23.0 ftz 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 <br /> 3 S=>NE 2 Metal Low-E Double Yes 0.56 0.32 106.7 ftz 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 <br /> 4 S=>NE 2 Metal Low-E Double Yes 0.54 0.31 9.3 ftz 7 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 <br /> 5 E=>NW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftz 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 <br /> 6 W=>SE 4 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 10 ft 4 in Drapes/blinds None <br /> 7 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 48.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 8 N=>SW 6 Metal Low-E Double Yes 0.56 0.28 46.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 <br /> 9 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 10 S=>NE 7 Metal Low-E Double Yes 0.54 0.31 23.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 11 W=>SE 9 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 12/30/2016 2:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 � <br /> � <br />