FORM �405-2014 <br /> . ' GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 606 ftz 273 ftz 78.5 ft 9.3 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000273 2659.6 146.01 274.59 .2523 5 <br /> � <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.9999 21.8 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump None HSPF:9 21.8 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER: 16.2 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 <br /> 2 Central Unit Split SEER: 16.225.2 kBtu/hr 756 cfm 0.85 2 sys#2 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ft2 <br /> DUCTS <br /> / —Supply---- ----Return— Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 1st Floor 6 525 ft2 1st Floor 166 ftz Default Leakage 1st Floor (Default) (Default) 1 1 <br /> 2 Attic 6 430 ft� 2nd Floor 155 ftz Default Leakage 2nd Floor (Default) (Default) 2 2 <br /> 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 <br />