Laserfiche WebLink
,_r __,� � <br /> FURM R405-2014, . <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIIVG CONSTRUCTION ' <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 sf ADS Builder Name. Lennar Homes <br /> street: 36083 Carriage Pine Court Permit ot��: City of Zephyrhills <br /> City,State,Zip: , FL, Permit Number• <br /> Owner - Lennar Homes Jurisdiction. 611600 <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Concrete Block-Int Insul,Exterior R=4 1 1378.00 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d. N/A R= ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a. Under Attic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned.floor area above grade(ftz) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftZ <br /> Conditioned floor area below grade(ftZ) 0 c. N/A R= ftz <br /> 11.Ducts R ftZ <br />� 7.-Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl, U=0.56 33.33 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl, U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a. Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems - - <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a. Electric Cap:40 gallons <br /> EF•0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft� b. Conservation features <br /> b.N/A R= ft2 None <br /> c. N/A R= ft� 15.Credits Pstat <br />, Total Proposed Modified Loads: 58.15 <br /> Glass/Floor Area. 0.081 PASS <br /> Total Baseline Loads: 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'1`����T.�� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,�'��- •• `=:4`;�0,�, <br /> Code. calculation indicates compliance �'�'"rr„;''`� '==�.�`\��� <br /> rb,, =:."'�°;�.�5� <br /> �"C? <br /> /. with the Florida Energy Code. � +`� �rr�i�_. ;;.. .:, <br /> PREPARED BY: �aV� ���'l�Vl Before construction is completed w� ; � '�' ' "�� <br /> s� r=�j��_ --. <br /> DATE: this building will be inspected for � :-'�.,��_ ;b� <br /> compliance with Section 553.908 � -��� ' .- ,� <br /> I he�eb certi that this buildin as desi ned, is in com liance Florida Statutes. , <br /> Y fY 9, 9 P '�!� . - :���. <br /> with the Florida Energy Code. �,�U'W�"�'.. <br /> OWNER/AGENT: BUILDING FFICIAL: <br /> - DATE: DATE: ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. - <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires�Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. - <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />