My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18396
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18396
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 10:08:16 AM
Creation date
12/19/2017 10:08:14 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18396
Building Department - Name
LENNAR HOMES LLC
Address
36083 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � ,i <br /> FORi�II R405-2014. , . <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 sf ADS Builder Name: Lennar Homes <br /> street: 36083 Carriage Pine Court Permit Oftice: City of Zephyrhills ' <br /> City,State,Zip: , FL, Permit Number• <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location. FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4 1 1378.00 ft� <br /> b. Frame-Wood,Adjacent R=11.0 288.00 ft2 <br /> 3. Number of units, if multiple family 1 c. N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= �z <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 <br /> a. Under Attic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic, Ret: Main,AH:Main 6 165.7 <br /> a. U-Factor• Dbl, U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor• Dbl, U=0.56 33.33 ft� �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor: Dbl, U=0.56 23.00 ft� <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a. Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a. Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF•0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b. N/A R= ft2 None <br /> c. N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.15 pASS <br /> Total Baseline Loads. 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'���?",q�,�. • <br /> this calculation are in compliance with the Florida Energy specifications covered by this y � � " O�, . <br /> �,: <br /> '%�,. ._s. <br /> Code. calculation indicates compliance ,r,�. ;,,, ' _._�;.�` ��, <br /> �ave /w/�G� with the Florida Energy Code. � •rr�rf�. '���::;::.�.�;�t�+;ti�G}. <br />, PREPARED BY: �W� Before construction is completed w ; ' � <br /> s� ;-:_-�f',:.. _.� ��G <br /> DATE: this building will be inspected for c,� , �;,;��'� <br /> compliance with Section 553.908 ,v � � •. �, <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. ` �• ' <br /> Y fY 9� 9 P �'.... � ��'s_ .: <br /> with the Florida Energy Code. �I.?,yyE'� -. <br /> OWNER/AGENT: BUILDING FFICIAL: <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handl enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. . _ <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage _ <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.