Laserfiche WebLink
I <br /> i <br /> i <br /> c_ y' I <br /> , I <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> � <br /> Project Name: 3127 sf ADS Builder Name: LENNAR HOMES i <br /> street: 6563 Paden Wheel Street Permit Office: Cl of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� ��.��� , <br /> Owner LENNAR HOMES .lurisdiction: 611600 <br /> Design Location: FL,Tampa � <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ � <br /> b Concrete Block-Int Insul,Exterior R=4 1 1309.80 ft <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ � <br /> 4 Number of Bedrooms 5 d.N/A R- ft= <br /> 10.Ceiling Types (1946.0 sqft.) Insulation Area � <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1772.00 ftZ � <br /> 6. Conditioned floor area above grade(ftZ) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 585 ! <br /> a. U-Factor• Dbl,U=0.54 162.68 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 <br /> � <br /> SHGC• SHGC=0.31 ' <br /> b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.20 � <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor Dbl,U=0.56 86.67 ft2 � ' <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 � <br /> SHGC• b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 4.213 ft. ' <br /> Area Weighted Average SHGC� 0.303 14 Hot water systems i <br /> a.Electric Cap�40 gallons <br /> 8. Floor Types (1772.0 sqft.) Insulation Area EF 0.950 � <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft� b. Conservation features ' <br /> b.Floor over Garage R=11.0 260.00 ftZ None I <br /> c.N/A R- ftZ 15.Credits Pstat <br /> I <br /> Total Proposed Modified Loads: 91.14 pASS � <br /> Glass/Floor Area: 0.117 � <br /> Total Baseline Loads: 90.86 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �����.'�`:q�� ' <br /> '''- ,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti, ,,.� ; 4•,, 0,�, <br /> Code. calculation indicates compliance ��f„�'' , `':s'�.��ti, ,�`�. <br /> �ave �1.��-r`c!� With the Florida Energy Code.' �+ rnut�.��'`%r,.,:_�`:;••:�"�,� � <br /> �:,,r.tsu.. <br /> PREPARED BY: '� Before construction is completed � --�- � ' <br /> t7 <br /> D A T E: this building will be inspected for � �}�'` � : <br /> compliance with Section 553.908 * �' "' ' °o <br /> Florida Statutes. l �S <br /> I hereby certify that this building,as designed, is in compliance � � ��. <br /> with the Florida Energy Code. � ��b�� <br /> OWNER/AGENT. BUILDING OFFICIAL. <br /> DATE: DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handle enclosure qualifies as i <br /> certified factory-sealed in accordance with R403.2.2.1. I <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage , � i <br /> test report in accordance with R402.4.1.2. I <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, I <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. � <br /> 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 � <br /> II <br />