Laserfiche WebLink
i <br /> � , <br /> FORM R405-2014 i <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method i <br /> Project Name: 3127 sf ADS Builder Name: LENNAR HOMES i <br /> street: 6563 Paden Wheel Street Permit Office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa i <br /> 1 New construction or existing New(From Plans) 9 Wall Types(2907.1 sqft.) Insulation Area � <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftz � <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftZ � <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ <br /> 4 Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z I <br /> , a.Under Attic(Vented) R=30.0 1772.00 ft <br /> 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ft� � <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ I <br /> 11.Ducts R ftz <br /> 7 Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 585 <br /> a. U-Factor• Dbl,U=0.54 162.68 ft2 b.Sup• Attic,Ret:2nd Floor,AH:2nd Floor 6 545 ' <br /> SHGC• SHGC=0.31 � <br /> b. U-Factor Dbl,U=0.56 117.00 ft2 12.Cooling systems kBtu/hr Efficiency ' <br /> SHGC� SHGC=0.28 a.Central Unit 25.2 SEER:16.20 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor: Dbl,U=0.56 86.67 ftz ' <br /> SHGC SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC� b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 4.213 ft. <br /> Area Weighted Average SHGC� 0.303 14 Hot water systems i <br /> a.Electric Cap:40 gallons <br /> B. FloorTypes (1772.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features <br /> b.Floor over Garage R=11.0 260.00 ftZ None <br /> c.N/A R= ftZ �5.Credits Pstat <br /> Glass/FloorArea: 0.117 Total Proposed Modified Loads� 91.14 pASS <br /> Total Baseline Loads: 90.86 <br /> ; <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'C�':�T.q?.� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti ,� ,� `"�:�; Q�,; <br /> Code. calculation indicates compliance �'�:r,,,,�'' , ,.:``;�-t +�+ <br /> wi t h t he F lori da Energy Co de. E+ ur�rr�,� "a'"�'�'�``,ti��7 I <br /> PREPARED BY: �QVe ���G� Before construction is completed � .-b.�•, �� `���., ":`,'���'" � <br /> D A T E. t hi s bui l di n g w i l l b e i n s p e c t e d f o r t�g. ��i�;� � . <br /> compliance with Section 553.908 * '° , . .� <br /> Florida Statutes. � �: <br /> I hereby certify that this building,as designed, is in compliance � �� <br /> with the Florida Energy Code. ��1�y�",�' <br />� OWNER/AGENT: BUILDING O FIC L. <br /> DATE. DATE. � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br />' certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. I <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ; <br />� tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. j <br /> I � <br /> 1/3/2017 12:24 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I <br />