Laserfiche WebLink
Y � <br /> FORM R405-2014 � <br /> ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method j <br /> , I <br /> Project Name: 3127 sf ADS � Builder Name. LENNAR HOMES ' <br /> street: 6563 Paden Wheel Street Permit office: C1ty of Zephyrhills �i <br /> City,State,Zip: ,FL, Permit Number <br /> Owner LENNAR HOMES ,lurisdiction: 611600 I <br /> Design Location: FL,Tampa � � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area { <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftz i <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz �, <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1772.00 ft <br /> 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ftZ � <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ I <br /> 11.Ducts R ftZ <br /> 7 Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 585 <br /> a. U-Factor Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 545 � <br />� SHGC• SHGC=0.31 � <br /> b. U-Factor Dbl,U=0.56 117.00 ftz 12.Cooling systems kBtu/hr E�ciency <br /> a.Central Unit 25.2 SEER:16.20 <br /> SHGC: SHGC=0.28 b.Central Unit 25.2 SEER:16.20 , I <br /> c. U-Factor Dbl,U=0.56 86.67 ftZ <br /> SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• IV/A ftZ a.Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 I <br /> Area Weighted Average Overhang Depth: 4.213 ft. { <br /> Area Weighted Average SHGC� 0.303 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> B. Floor Types (1772.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features <br /> b.Floor over Garage R=11.0 260.00 ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat I <br /> Total Proposed Modified Loads: 91.14 pASS <br /> Glass/Floor Area: 0.117 I <br /> Total Baseline Loads. 90.86 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�'�E�T1q1.�- . <br /> this calculation are in compliance with the Florida Energy specifications covered by this �, ,, ~ (,��, <br />' Code. calculation indicates compliance ��n,,''' l``='.,�`. +� � <br /> �aVe �/��G� with the Florida Energy Code. F^+ rar+rr�''% ''•���°�"��sti O , <br /> PREPARED BY: P �� '�.l �"���� <br /> W� Before construction is com leted c� � � <br /> � C,;w C7 � <br /> DATE: this building will be inspected for � ).,,�;- �,. . � <br /> compliance with Section 553.908 * �-° ,. : -�, <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �",�, ,_ ���.. i <br /> with the Florida Energy Code. , ��D y�E'� j <br /> OWNER/AGENT. BUILDING OFFICI L. I <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. I <br /> 1/3/2017 12:24 PM EnergyGauge�USA=FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I II <br />