My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18519
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18519
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:07:49 PM
Creation date
5/1/2018 1:07:48 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18519
Building Department - Name
LENNAR HOMES LLC
Address
36078 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f � <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method � <br /> Project Name: 1941 sf ADS - Builder Name: Lennar Homes i <br /> street: 36078 Stable Wilk Avenue Perr„�t o�ice: City of Zephyrhills I <br /> City,State,Zip: ,FL, Pertnit Number , <br /> Owner Lennar Homes Jurisdiction: 611600 � <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ft� <br /> 3. Number of units,if multiple family 1 c.N/A � <br /> R= ft <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ , <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1594.00 ft2 <br /> 6. Conditioned floor area above grade(ftZ) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft' <br /> 11 Ducts R ft' <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> Ia. U-Factor • Dbl,U=0.54 101.00 ft' � <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ft= <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft' b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads. 58.15 pASS <br /> Glass/Floor Area: 0.081 <br /> Total Baseline Loads: 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'C��T•q?.,�. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ^v,,.� "' ��,� +�. <br /> Code. calculation indicates compliance ��:.,,;'` ';=;�'�.�.�. <br /> t-�r�,tltur.�.'�: .,:5��"'c �+k````_�L�`O <br /> ,{/,,� with the Florida Ener Code. �' ` `'`�-'''`� „ _ <br /> PREPARED BY. ri �G� 9Y � �'''��r �:;��, <br /> �aVe Wl Before construction is completed w � �r � <br /> DATE. this building will be inspected for ��,ry:. �' '�;'k'.".-- � <br /> �(;i <br /> compliance with Section 553.908 * �"� ' , � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,,�,, ��� <br /> with the Florida Energy Code. D WE'� <br />, OWNER/AGENT: BUILDING OFFICI L. <br /> DATE. DATE: ' � <br /> � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with-R402.4.1.1 and an envelope leakage , <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.