My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18519
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18519
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:07:49 PM
Creation date
5/1/2018 1:07:48 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18519
Building Department - Name
LENNAR HOMES LLC
Address
36078 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ; <br /> Project Name: 1941 sf ADS Builder Name: Lennar Homes I <br /> street: 36078 Stable Wilk Avenue Pem,it ot�ce: City of Zephyrhills � <br /> City,State,Zip: ,FL, Pertnit Number. ' <br /> Owner• Lennar Homes Jurisdiction: 611600 � <br /> Design Location: FL,Tampa , i <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ft' ' <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ft2 ' <br /> 3. Number of units,if multiple family 1 c.N!A z <br /> R= ft <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ , <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1594.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' <br /> 11 Ducts R ft' <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor Dbl,U=0.54 101.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ft' �Z.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ � <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area VVeighted Average SHGC: 0.308 14 Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft' b. Conservation features <br /> b.N/A R= ft� None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 58.15 pASS <br /> Total Baseline-Loads: 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �,��'S�.�T,q?,� - <br /> this calculation are in compliance with the Florida Energy specifications covered by this �w ,�� � '"'=;.,, t7, <br />' Code. calculation indicates compliance ��'�,�' '==�'`�.� �. � <br /> �•.<rrrrr,.=,,,,;•.,;,<��°:,�„x.'�`",ti�0 . <br />� /, with the Florida Energy Code. �''��` �``::°'``�` <br /> PREPARED BY: �G�Ve f�GO��'IGYI � ' ` ��'��"" <br /> Before construction is completed w. �;r � <br /> DATE: � this building will be inspected for � `"'�;,_��'." ; a <br /> compliance with Section 553.908 * �'� � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. •�,,�;� , ����.. <br /> wi h h F rida En r � " `"C� <br /> t t e lo e Code. D <br /> 9Y WE <br /> OWNER%AGENT. BUILDING OFFICI . <br /> DATE: DATE: � � � i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. I <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage , <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.