Laserfiche WebLink
!. - i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ; <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method ; <br /> . , <br /> Project Name: 1941 sf ADS Builder Name: Lennar Homes <br /> street: 36078 Stable Wilk Avenue Permit O�ce: Cl�����hyrhills <br /> City,State,Zip: ,FL, Permit Number � <br /> Owner• Lennar Homes Jurisdiction: 6116�0 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ft' <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ , <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftZ ' <br /> z <br /> Conditioned floor area below grade(ft2) 0 11 cDucts R R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ft' 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ft' � <br /> SHGC� SHGC=0.28 13.Heating systems kBtulhr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 58.15 pASS <br /> Glass/Floor Area: 0.081 <br /> Total Baseline Loads: 58.52 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�.'C��T'.�?� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ^F.•,� � �;��` Q�,, � <br /> Code. calculation indicates compliance r,s�a;,s `-=��i �. <br /> ,{ w i t h t h e F l o r i d a E n e r g y C o d e. � nr r r t�"�r:•`,`;`=�"����:�,t C>. � <br /> J7Gt�� GO��'IGG� :. -.,,n:++�.. � <br /> PREPARED BY. �'f Before construction is completed �: �r <br /> DATE: this building will be inspected for �."`"�" ' . � <br /> compliance with Section 553.908 ,� '� ' �� � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. t�, � _ . ��� , <br /> with the Florida Energy Code. ���WE� <br /> OWNER/AGENT: BUILDING OFFICIA � <br /> DATE. ' DATE. � <br /> - Compliance requires cettification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />