My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18520
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18520
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:09:24 PM
Creation date
5/1/2018 1:09:22 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18520
Building Department - Name
LENNAR HOMES LLC
Address
6575 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ' <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES i <br /> street: 6575 Paden Wheel Street Permit office: C�,�tX�Zephyrhills <br /> City,State,Zip: ,FL, Permit Number I E� !T <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2031.60 ft� <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 ' <br /> 4 Number of Bedrooms 4 - d.N/A R= ft2 , <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area z <br /> a.Under Attic(Vented) R=30.0 2193.00 ft <br /> 6. Conditioned floor area above grade(ft2) 2599 b.Cathedral/Single Assembly(Vented) R=30.0 407.00 ft� <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11 Ducts R ftZ <br /> 7 Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 <br /> a. U-Factor Dbl,U=0.54 141.68 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 72.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 43.5 SEER:15.50 <br /> c. U-Factor• Dbl,U=0.56 48.00 ft' <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> r d. U-Factor� other(see details) 38.50 ft' a.Electric Heat Pump 43.5 HSPF:9.00 <br /> I SHGC: other(see details) <br /> Area Weighted Average Overhang Depth. 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems <br /> S. Floor Types (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.850 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft' b. Conservation features <br /> b.N/A R= ft� None <br /> c.N/A R= ft2 15.Credits Pstat � <br /> Glass/Floor Area: 0.115 Total Proposed Modified Loads: 75.53 pASS � <br /> Total Baseline Loads: 78.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and fl�'£��`T�1.� • <br /> this calculation are in compliance with the Florida Energy specifications covered by this �4. ,��Q <br /> Code. calculation indicates compliance ���,,,;'r� _-:;`,,,ti`.�*s <br /> F�, arrr�"` ``''A:.'�<,*�t`"`�` <br /> �a�e �Gol�r'c!� �✓ith the Florida Energy Code. 4, f�;••.,;,.-:"�;{,�„ti � <br /> PREPARED BY' Before construction is completed w. ' �;; �" �-• , <br /> DATE. this building will be inspected for ���,:��:''j��. :� ' <br /> compliance with Section 553.908 � � '� � <br />� I hereby certify that this building,as designed, is in compliance Florida Statutes. � /f� � <br /> with the Flonda Energy Code. / {�/ ��D�y�'� <br /> �/t/ <br /> OWNER/AGENT. BUILDING OFFICI . <br /> DATE: DATE. � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Gompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. , <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 9:20 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.