Laserfiche WebLink
r� <br /> S ' <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ' <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES , <br /> street: 6575 Paden Wheel Street Perrr,it o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner LENNAR HOMES Jurisdiction: 6116�0 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(24�0.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2031.60 ft' <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft' <br /> 3. Number of units,if multiple family 1 c.N/A z <br /> R= ft <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area ; <br /> a.Under Attic(Vented) R=30.0 2193.00 ftz <br /> 6. Conditioned floor area above grade(ft2) 2599 b.Cathedral/Single Assembly(Vented) R=30.0 407.00 ft' , <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 <br /> a. U-Factor• Dbl,U=0.54 141.68 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 72.00 ftZ �2.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 43.5 SEER:15.50 <br /> , c. U-Factor: Dbl,U=0.56 48.00 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor other(see details) 38.50 ft2 a.Electric Heat Pump 43.5 HSPF:9.00 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14.Hot water systems <br /> 8. Floor Types (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft2 b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 75.53 pASS <br /> Glass/Floor Area: 0.115 <br /> Total Baseline Loads: 78.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��T��Tlq?,�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this � �. ,� ' � �,.� Q�, . <br /> Code. calculation indicates compliance �'�,,,,`''�' '=_��w�� ,��„ <br /> with the Florida Ener Code. � 1rrr:�'��:�.` <br />