My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18521
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18521
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:10:37 PM
Creation date
5/1/2018 1:10:36 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18521
Building Department - Name
LENNAR HOMES LLC
Address
36089 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Job: 2386sfADS <br /> Date: 3l22/2017 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - • • <br /> For Lennar Homes <br /> Notes: <br /> , - s e e <br /> Weather. Tampa International AP, FL, US II <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db ._91 °F ' <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 �F <br /> Daily range L, <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 28126 Btuh Structure 29048 Btuh <br /> Ducts 4025 Btuh Ducts 4489 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 32151 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 33538 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 4417 Btuh <br /> Ducts 812 Btuh <br /> Heating Cooling Central vent (0 cfm) 0 Btuh <br /> Area(ft2 2389 2389 Equipment latent load 5229 Btuh <br /> Volume�ft') 21698 21698 <br /> Air changes/hour 0.28 0.15 Equipment total load 38766 Btuh <br /> Equiv.AVF (cfm) 101 54 Req. total capacity at 0.85 SHR 3.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-042-230-18 Cond 14HPX-042-230-18 <br /> AHRI ref 5187377 Coil CBX27UH-042-230*++TDR <br /> AHRI ref 5187377 <br /> Efficiency 9 HSPF Efficiency 13.0 EER, 15.5 SEER <br /> Heating input Sensible cooling 36975 Btuh <br /> Heating output 43500 Btuh @ 47°F Latent cooling 6525 Btuh <br /> Temperature rise 28 °F Total cooling 43500 Btuh <br /> Actual air flow 1400 cfm Actual air flow 1400 cfm <br /> Air flow factor 0.044 cfm/Btuh Air flow factor �.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .�. WCI htsoft" 2017-Mar-2214:33:39 <br /> g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 7 <br /> � H:\LENNAR LOADS�2386 sf ADS 3.5 ton.rup Calc=MJ8 Front Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.