My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18521
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18521
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:10:37 PM
Creation date
5/1/2018 1:10:36 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18521
Building Department - Name
LENNAR HOMES LLC
Address
36089 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2386sfADS <br /> Date: 3/22/2017 . <br /> En fire Ho use By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' o - s s <br /> For• Lennar Homes <br /> • s e • • <br /> Design Conditions <br /> Outdoor design DB. 91.3°F Sensible gain: 33538 Btuh Entering coil DB� 75.6�F <br /> .Outdoor design WB: 77.3°F Latent gain: 5229 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 38766 Btuh <br /> Indoor RH: 50% Estimated airflow� 1400 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-042-230-18+CBX27UH-042-230*++TDR <br /> Actual airtlow: 1400 cfm <br /> Sensible capacity� 36975 Btuh 110% of load <br />� Latent capacity: 6525 Btuh 125% of load <br /> Total capacity� 43500 Btuh 112% of load SHR. 85% <br /> • a a <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 32151 Btuh Entering coil DB. 69.7°F <br /> Indoor design DB. 70.O�F <br /> Manufacturer's PerFormance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer• Lennox Model: 14HPX-042-230-18+CBX27UH-042-230*++TDR <br /> Actual airtlow: 1400 cfm <br /> Output capacity: 43500 Btuh 135% of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a � <br /> Actual airflow: 1400 cfm <br /> Output capacity� 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> .` wri htsoft` 2017-Mar-2214:33:39 <br /> �, 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\2386 sf ADS 3.5 ton.tup Calc=MJ8 Front Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.