, , <br /> � 7 � <br /> • . • � i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION I <br /> � <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method '� <br /> - � <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES <br /> street: 6539 Paden Wheel Street Pem,�t o�ir.e: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner LENNAR HOMES Jurisdiction: 61 j(QQ , <br /> Design Location: FL,Tampa - , <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft' <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft� <br /> 3. Number of units,if multiple family 1 c.N/A = <br /> R= ft I <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=3�.0 2193.00 ft i <br /> 6. Conditioned floor area above grade(ft=) 2599 b.Cathedral/Single Assembly(Vented) R=30.0 407.00 ftZ � <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ i <br /> 11 Ducts R ft2 <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 ' <br /> a. U-Factor Dbl,U=0.54 141.68 ftz , <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 72.00 ft� 12.Cooling systems kBtu/hr Efficiency ; <br /> SHGC: SHGC=0.32 a.Central Unit 43.5 SEER:15.50 I <br /> c. U-Factor• Dbl,U=0.56 48.00 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency I <br /> d. U-Factor other(see details) 38.50 ft' a.Electric Heat Pump 43.5 HSPF:9.00 I <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. i <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems <br /> a.Electric Cap:40 gallons � <br /> 8. Floor Types (2599.0 sqft.) Insulation Area EF.0.950 I <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None � <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area. 0.115 Total Proposed Modified Loads: 75.53 pASS � <br /> Total Baseline Loads: 78.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'�:ST��� ` <br /> this calculation are in compliance with the Florida Energy specifications covered by this '4, , ' _��,, p�, �-. <br /> Code. calculation indicates compliance ��fr,r°p`?"�, t _,'`w`���. <br /> �ave �{'��Y6 with the Florida Energy Code. H -trrdrr�'.'��:r:��='�'°�°�•��'�-,�•O. � <br /> :� �?:ti,,�:�„ <br /> PREPARED BY. � Before construction is completed w.� ' � <br /> FG. :.__�t�, l'I <br /> DATE. this building will be inspected for �,ry. l„�;: " �: <br /> •.� : .� . <br /> _ compliance with Section 553.908 � - � <br /> Florida Statutes. :s� �p <br /> I hereby certify that this building, as designed, is in compliance � �� i, <br /> with the Florida Energy Code. 4D'yy6"� <br /> OWNER/AGENT. BUILDING FFICIA . <br /> DATE: DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handle nclosure qualifies as � _ <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ; <br /> test report in accordance with R402.4.1.2. <br /> - C,ompliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. , <br /> 1/3(2017 9:20 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />