Laserfiche WebLink
z � <br /> FORM R405-2014 - <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method ', <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES <br /> street: 6539 Paden Wheel Street Pem,�t ot�r.�: City of Zephyrhills i <br /> City,State,Zip: ,FL, Permit Number <br /> Owner LENNAR HOMES Jurisdictian. 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area i <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ftz I <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft2 ' <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 ; <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2193.00 ft �i <br /> 6. Conditioned floor area above grede(ft=) 2599 b.Cathedral/Single Assembly(Vented) R=30.0 407.00 ft2 ; I <br /> z <br /> Conditioned floor area below grade(ftZ) 0 11 DNcts R R ft' I <br /> 7 Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 � <br /> a. U-Factor: Dbl,U=0.54 141.68 ftZ � �I <br /> SHGC: SHGC=0.31 � <br /> b. U-Factor Dbl,U=0.58 72.00 ft� �Z•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 43.5 SEER:15.50 '� <br /> c. U-Factor Dbl,U=0.56 48.00 ftZ � i <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency I I <br /> d. U-Factor� other(see details) 38.50 ft2 a.Electric Heat Pump 43.5 HSPF:9.00 � <br /> SHGC: other(see details) � <br /> Area Weighted Average Overhang Depth: 5.520 ft. ' <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems � <br /> a.Electric Cap:40 gallons , <br /> 8. Floor Types (2599.0 sqft.) Insulation Area � <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft2 b. Conservation features i <br /> b.N/A R= ft' None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.115 Total Proposed Modified Loads. 75.53 � A �+�+ <br /> Total Baseline Loads. 78 49 ��������� ' <br /> I <br /> � <br /> I hereb certi that the lans and s ecifications covered b Review of the lans and �� I <br /> Y fY P P Y P ��'; j4�^�_ i <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' 4. ,�, ' _ _ Or,�, <br /> . <br /> Code. calculation indicates compliance ��>��t�' ,:::,�,t,�`���. ' ; <br /> with the Florida Energy Code. � �+r��"��.� �:�"_�'�'�'' O. <br /> /, � _ rri?�^ i:;' -�;;.:.+�"` ' <br /> PREPARED BY' �ave ����Y` Before construction is completed w � ' <br /> � <br /> this buildin will be ins ected for � ��•`` � � � <br /> DATE: 9 P t9 �� : I <br /> �.� I <br /> compliance with Section 553.908 ,: � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �+�, '- . ��� <br /> G'p�� .� � <br /> with the Florida Energy Code. WE <br /> I' � <br /> OWNER/AGENT. BUILDING OF ICIAL. - � <br /> DATE: DATE. i <br /> 1 <br /> - Compliance requires certification by the air handler unit manufacturer that the ai[handler e closure qualifies as �I <br /> certified factory-sealed in accordance with R403.2.2.1. �� <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage I <br /> test report in accordance with R402.4.1.2. ' <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. � <br /> 1/3/2017 9:20 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br /> I <br />