My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18613
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18613
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:42:49 AM
Creation date
5/2/2018 6:42:47 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18613
Building Department - Name
LENNAR HOMES LLC
Address
36065 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , <br /> FORM R405-2014 ; <br /> FLORIDA ENERGY EFFICIENCY �ODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name. 1941 sf ADS _. Builder Name: Lennar Homes � <br /> street: 36065 Stable Wilk Avenue Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number r��l3 <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa Counry:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ft' <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area II <br /> 5. Is this a worst case? Yes (Vented R=30.0 1594.00 ft2 <br /> a.Under Attic ) , <br /> 6. Conditioned floor area above grade(ft2) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftZ � <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11 Ducts R ftZ <br /> 7 Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165.7 � <br /> a. U-Factor Dbl,U=0.54 101.00 ft= � <br /> SHGC: SHGC=0.31 , <br /> b. U-Factor Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ � <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency j <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 � <br /> SHGC: '� <br /> Area Weighted Average Overhang Depth. 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons i <br /> EF 0.950 � <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ft2 15.Credits Pstat <br />� Glass/Floor Area. 0.081 Total Proposed Modified Loads. 56.51 pASS <br /> Total Baseline Loads: 61.28 <br /> i <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'C�.Sr�q�. ! I <br />, this calculation are in compliance with the Florida Energy specifications covered by this '�� + '" =_�'�Q�, . <br /> Code. calculation mdicates compliance ��r,;t;'T '=_�;�`. .*�. II <br /> �, . .�:a.'..� ,u�r" � <br /> f`* qr,�r;:.,6, ;,`-:.52ni.�`��i <br /> �a�e ,{��G/, with the Florida Energy Code. ' � ""�"��,�„� O. � <br /> � �'::'"•. . . � � <br /> PREPARED BY: ri �� Before construction is completed �� ��� �, <br /> DATE: this building will be inspected for � 'i,:f`� ,� <br />, compliance with Section 553.908 * �''� � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ' . .�,�, "� ���. <br /> I with the Florida Energy Code. . ��D yyE`C� I <br /> OWNER/AGENT. BUILDING OFFICIAL. i <br /> DATE. • 3•' DATE: a` ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br /> test report in accordance with R402.4.1.2. ' <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, � <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 3/30/2017 8:41 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.