My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18613
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18613
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:42:49 AM
Creation date
5/2/2018 6:42:47 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18613
Building Department - Name
LENNAR HOMES LLC
Address
36065 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f � ` <br /> FORM R405-2014 � ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method , <br /> Project Name. 1941 sf ADS Builder Name: Lennar Homes , <br /> street: 36065 Stable Wilk Avenue Perm�t otece: City of Zephyrhills � <br /> City,State,Zip: ,FL, Permit Number � <br /> Owner Lennar Homes Jurisdiction: 611600 ' <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1666.0 sqft.) Insulation Area <br /> a.Concrete Block-Int Insul,Exterior R=4.1 1378.00 ft2 i <br /> 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=11.0 288.00 ftZ � <br /> � <br /> 3. Number of units,if multiple family 1 c.N/A R= � <br /> 4 Number of Bedrooms 4 d.N/A R- ft� � <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1594.00 ft <br /> 6. Conditioned floor area above grade(ft=) 1936 b.Cathedral/Single Assembly(Vented) R=30.0 342.00 ftZ , <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11 Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.5up:Attic,Ret:Main,AH:Main 6 165.7 <br /> a. U-Factor Dbl,U=0.54 101.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency - <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.950 � <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b.N/A R= ft' None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads. 56.51 pASS <br /> Total Baseline Loads: 61.28 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'C�E,�?'.q�.�. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ''4� ,�,;� 'a_;;,: t��,, � <br /> Code. calculation indicates compliance r,�'��.r,;T ;_. ``` �' <br /> with the Florida Energy Code. �, frr;r,�'"``:s-�'�:�s,+��"`,},�{� <br /> PREPARED BY: P � �� ��. � �� <br /> �ave �Gol�rcl� Before construction is com leted � � , <br /> DATE: this building will be inspected for ��,ry . "'°���"" � � <br /> compliance with Section 553.908 • �''� ;� <br /> Florida Statutes. �' �. � � <br /> I hereby certify that this building, as designed, is in compliance �, y��s , ' <br /> with the Florida Energy Code. d�•W�� . <br /> OWNER/AGENT: BUILDING FI�IAL: <br /> DATE: DATE. �' <br /> I <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. , . <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 3/30/2017 8:41 AM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.