Laserfiche WebLink
Y- � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ' <br /> Project Name: 1791 sf ADS Builder Name: Lennar Homes <br /> screet: 36077 Stable Wilk Avenue Permit Office: Cl�of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number:� �o( <br /> Owner• Lennar Homes Jurisdiction: 611600 � � <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area � <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft' <br /> I <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units, if multiple family 1 c.N/A � <br /> R= ft , <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes �0.Ceiling Types (1817.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1533.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284 00 ftZ <br /> z <br /> Conditioned floor area below grade(ftZ) 0 11 cDucts R R ft2 � <br /> 7 Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220 <br /> a. U-Factor Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 ' <br /> b. U-Factor Dbl,U=�.56 33.33 ftZ �2•Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ft' <br /> SI1GC: SHGC=0.28 13.Heating systems kBtu/hr E�ciency , <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 26.4 HSPF:9.00 � <br /> SHGC: � - I <br /> � <br /> Area Weighted Average Overhang Depth: 1.233 ft. , <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems � <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features <br /> b.N/A R= ft' None , <br /> c.N/A - R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 54.39 pASS <br /> Total Baseline Loads: 58.04 , <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'C�STIq?,�, I <br /> this calculation are in compliance with the Florida Energy specifications covered by this �'�r , � "`,s'�., Q ' <br /> Code. calculation indicates com liance �ril°'' ``-'r.4`.� � <br /> P �+s. �.q�:��.. .,=:�:.�,�, {. <br /> /' with the Florida Energy Code. � tr�rrr^�'+��.,";�"'.��<<�,� �� � <br /> PREPARED BY �aVe �����'c Before construction is completed ,w� � ' � � <br /> :���, - � :p. <br />, DATE. this building will be inspected for �,ry �. �,. <br /> l�: .. <br /> compliance with Section 553.908 .*. � �' . ,�. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � , �� <br /> with the Florida Energy Code. � „1?;{�y�`�� <br /> OWNER/AGENT: BUILDING OFFICI L. <br /> DATE: DATE. �-"�- t � ' <br /> I � <br /> - Compliance requires certifcation by the air handler unit manufacturer that the air handler enclosure qualifies as i <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> fest report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />� I <br />