Laserfiche WebLink
� � <br /> , ' ' <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 1791 sf ADS Builder Name: Lennar Homes <br /> street: 36077 Stable Wilk Avenue Perm�t offce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar Homes Jurisdiction: 611600 ; <br /> Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) I <br /> I <br /> 1. New construction or existing New(From Plans) 9. WaII�Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft' i <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4 Number of Bedrooms 4 d.N/A R= ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) \ R=30.0 1533.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284.00 ft� <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft' ' <br /> 11.Ducts R ft' <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220 <br /> a. U-Factor Dbl,U=0.54� 87.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=�.56 33.33 ft2 12•Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=028 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 26.4 HSPF:9.00 <br /> SHGC: � <br /> Area Weighted Average Overhang Depth. 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N/A R= ft= None � <br /> c.N/A R= ftZ 15.Credits Pstat , <br /> Total Proposed Modified Loads: 54.39 <br /> Glass/Floor Area: 0.079 PASS <br /> Total Baseline Loads: 58.04 <br /> I <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'C���T�?•,�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this 'tv , � "!_�,,, �.7,�,� i <br /> Code. calculation indicates compliance ���i�,s'` , =;:`;����,_ . I <br /> with the Florida Energy Code. �`+. ur:,:s�'+:•:=��:.�`��,,;;,�O. <br /> �aV2 ���1G�1 � :: ,,,. � <br /> PREPARED BY: Before construction is completed ,��, �.�,� � , <br /> DATE: this building will be inspected for - Lry. �„�" :w* <br /> compliance with Section 553.908 �. �`� � � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. e��,� , -__ . ���� <br /> with the Florida Energy Code. �WE� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: � DATE. - ' � - ' <br /> � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn.requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in aocordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />