My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18614
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18614
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:44:03 AM
Creation date
5/2/2018 6:44:01 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18614
Building Department - Name
LENNAR HOMES LLC
Address
36077 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� s <br /> � • i <br /> FC�RM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> � <br /> . � <br /> Project Name: 1791 sf ADS Builder Name: Lennar Homes ' <br /> street: 36077 Stable Wilk Avenue Perrt,it o�ice: City of Zephyrhills � <br /> City,State,Zip: ,FL, Permit Number: � <br /> Owner• Lennar Homes Jurisdiction: 611600 � <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) �' <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area I <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 i <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft� <br /> 3. Numlier of units,if multiple family 1 c.N/A R= ft' , <br /> 4. Number of Bedrooms 4 d.N/A R= ft' <br /> b. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area 2 <br /> - a.Under Attic(Vented) R=30.0 1533.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1817 b.Cathedral/Single Assembly(Vented) R=30.0 284.00 ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 , <br /> 11 Ducts R ft� <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 220 <br /> a. U-Factor: Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency � <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ft� <br /> -SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft= a.Electric Heat Pump 26.4 HSPF:9.00 � <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons � <br /> 8. Floor Types (1817.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N/A R= ft' None <br /> : <br /> c.N/A R= ft 15.Credits Pstat � <br /> Total Proposed Modified Loads: 54.39 pASS I <br /> Glass/Floor Area: 0.079 <br /> Total Baseline Loads: 58.04 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0�'����'.�#r�, , <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti ,:. "!�,+. 0,�,. <br /> .�`, .�. <br /> Code. calculation indicates compliance �, 'ir,°r' , 4.=:=��f�'��� ,�• <br /> �ave �/��G� with the Florida Energy Code. � rrrarr�''=,.;,:��j rt��,,,,,t � � <br /> PREPARED BY� Wl Before construction is completed ,w�, ���� � <br /> DATE: this building will be inspected for try_ �Ef(i.-. �* � <br /> compliance with Section 553.908 *' �� ',�- <br /> I hereby certify that this building,as designed, is in compliance Flonda Statutes. �,,�; �r�+� <br /> with the Florida Energy Code. G��•ti1'E`� <br /> OWNER/AGENT. BUILDIN OFFICI . <br /> DATE: DATE: ������ � '� <br /> I <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as i <br /> certified factory-sealed in accordance with R403.2.2.1. , <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage , <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 3/30/2017 8:19 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.