Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:46:36 AM
Creation date
5/2/2018 6:46:34 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVEARDO
Building Department - Doc Type
Permit
Permit #
17-18616
Building Department - Name
LENNAR HOMES LLC
Address
36060 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F � , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFfCIENCY CODE FOR BUILDIRlG CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> � <br /> Project Name: 1871 sf ADS elev B Builder Name: Lennar Homes � <br /> screet: 36060 Stable Wilk Avenue Permit Office: Cl-Ly���phyrhills � <br /> City,State,Zip: ,FL, Permit Number � I <br /> Owner• Lennar Homes Jurisdiction: 61160 � <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> I <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area I <br /> a.Frame-Wood, Exterior R=11.0 1152.00 ft2 � + <br /> 2. Single family or multiple family Single-family , <br /> b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft2 �• <br /> 4 Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? 10.Ceiling Types (1090.0 sqft.) Insulation Area I <br /> Yes a.Under Attic(Vented) R=30.0 1090.00 ftZ ' <br /> 6. Conditioned floor area above grade(ftZ) 1870 b.N/A R= ftZ � <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz i <br /> 11 Ducts R ft2 � <br /> 7 Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 � <br /> a. U-Factor Dbl,U=0.54 87.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 49.69 ftz 12.Cooling systems kBtu/hr E�ciency. <br /> SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 <br /> ! <br /> c. U-Factor Dbl,U=0.56 33.33 ftZ ; <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency � <br /> d. U-Factor N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 i <br /> SHGC: ; <br /> Area Weighted Average Overhang Depth: 1.369 ft. � <br /> Area Weighted Average SHGC: ' 0.303 14 Hot water systems ; - <br /> 8. Floor Types (1870.0 sqft.) Insulation Area a.Electric Cap:40 gallons ' <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 647.00 ft' None � <br /> c.other(see details) R= 443.00 ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.79 pASS � <br /> Total Baseline Loads. 63.98 i <br /> I <br /> � <br /> I hereby certify that the plans and specifications covered by Review of the plans and �����"'.��.� . i <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��, ,e"',�4:` +��,�,, I <br /> o- <br /> Code. calculation indicates compliance �'��i,��`�'�` `_`'"'�a�`. .�`. <br /> with the Florida Energy Code. # �rF;r�`.'�r�.===°��',��i`,;z�0. � <br /> PREPARED BY: �GII�e f�G�j'IGGI Before construction is completed w. � . �� � I <br /> ��^��� _f...,:. . .t� <br /> DATE: this building will be inspected for �,ry. ":��` . �,. � <br /> compliance with Section 553.908 $ �'� ,� ; <br /> Florida Statutes. t j <br /> I hereby certify that this building,as designed, is in compliance '+�+ �.;�� <br /> with the Florida Energy Code. �'�1?yy�,`� ; <br /> � <br /> OWNER/AGENT. BUILDING FF IAL. I <br /> DATE: DATE: '- � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler e c sure qualifies as ! <br /> certified factory-sealed in accordance with R403.2.2.1. i <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ; <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. , <br /> 5/30/2017 1 44 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> I <br />, i <br />