._ �
<br /> • " • . i
<br /> FORM R405-2014
<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> Florida Department of Business and Professional Regulation - Residential Performance Method ,
<br /> Project Name: 1871 sf ADS elev B Builder Name: Lennar Homes ;
<br /> street: 36060 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills j
<br /> City,State,Zip: ,FL, Permit Number
<br /> Owner Lennar Homes Jurisdiction: 611600
<br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) I
<br /> 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area ,
<br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ftZ ,
<br /> b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ftz
<br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft2
<br /> 4. Number of Bedrooms 4 d.N/A R= ft'
<br /> 10.Ceiling Types (1090.0 sqft.) Insulation Area
<br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1090.00 ftz
<br /> 6. Conditioned floor area above grade(ft2) 1870 , b.N/A R= ft2
<br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ '
<br /> 11 Ducts R ft�
<br /> 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374
<br /> a. U-Factor• Dbl,U=0.54 87.00 ftZ '
<br /> SHGC: SHGC=0.31
<br /> b. U-Factor Dbl,U=0.56 49.69 ftZ 12•Cooling systems , kBtu/hr E�ciency
<br /> SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00
<br /> c. U-Factor Dbl,U=0.56 33.33 ft'
<br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency '
<br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
<br /> SHGC: �
<br /> Area Weighted Average Overhang Depth. 1.369 ft. ,
<br /> Area Weighted Average SHGC� 0.303 14 Hot water systems
<br /> a.Electric Cap:40 gallons
<br /> 8. Floor Types (1870.0 sqft.) Insulation Area EF 0.950
<br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft2 b. Conservation features
<br /> b.Floor Over Other Space R=0.0 647.00 ftz None �
<br /> c.other(see details) R= 443.00 ft2 15.Credits ' Pstat
<br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads. 61.79 pASS
<br /> Total Baseline Loads: 63.98
<br /> I hereby certify that the plans and specifications covered by Review of the plans and �'�'C�'�rQ?.,�. � -
<br /> this calculation are in compliance with the Florida Energy specifications covered by this ,� ,� _� �'7�,, .
<br /> Code. calculation indicates compliance rr,`C'r,,,�, :_`-_,-'.,���.*�lt�. .
<br /> /, with the Florida�Energy Code. ��rF�rr��.�.°:�:.�•;�,��,,'�,�„ti � ',
<br /> PREPARED BY. �aVe �����'` Before construction is completed w�����r; .� d ;
<br /> DATE. this building will be inspected for try. �;;:��:E� s}
<br /> compliance with Section 553.908 •* �''� �-
<br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,� �,. . ���+ ,
<br /> with the Florida Energy Code. � ��a�S'E`� ;
<br /> OWNER/AGENT: BUILDING O FICIAL.
<br /> DATE: DATE: - - ,
<br /> - Compliance reguires certification by the air handler unit manufacturer that the air handler e closure qualifies as �
<br /> certified factory-sealed in accordance with R403.2.2.1. ,
<br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
<br /> test report in accordance with R402.4.1.2.
<br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, '
<br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
<br /> 5/30/2017 1 44 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5
<br /> �
<br /> I
<br />
|