Laserfiche WebLink
._ � <br /> • " • . i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method , <br /> Project Name: 1871 sf ADS elev B Builder Name: Lennar Homes ; <br /> street: 36060 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills j <br /> City,State,Zip: ,FL, Permit Number <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) I <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area , <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ftZ , <br /> b.Concrete Block-Int Insul,Exterior R=4 1 846.44 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 362.56 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft' <br /> 10.Ceiling Types (1090.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1090.00 ftz <br /> 6. Conditioned floor area above grade(ft2) 1870 , b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ ' <br /> 11 Ducts R ft� <br /> 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 <br /> a. U-Factor• Dbl,U=0.54 87.00 ftZ ' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 49.69 ftZ 12•Cooling systems , kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ft' <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency ' <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: � <br /> Area Weighted Average Overhang Depth. 1.369 ft. , <br /> Area Weighted Average SHGC� 0.303 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1870.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 647.00 ftz None � <br /> c.other(see details) R= 443.00 ft2 15.Credits ' Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads. 61.79 pASS <br /> Total Baseline Loads: 63.98 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'�'C�'�rQ?.,�. � - <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,� ,� _� �'7�,, . <br /> Code. calculation indicates compliance rr,`C'r,,,�, :_`-_,-'.,���.*�lt�. . <br /> /, with the Florida�Energy Code. ��rF�rr��.�.°:�:.�•;�,��,,'�,�„ti � ', <br /> PREPARED BY. �aVe �����'` Before construction is completed w�����r; .� d ; <br /> DATE. this building will be inspected for try. �;;:��:E� s} <br /> compliance with Section 553.908 •* �''� �- <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,� �,. . ���+ , <br /> with the Florida Energy Code. � ��a�S'E`� ; <br /> OWNER/AGENT: BUILDING O FICIAL. <br /> DATE: DATE: - - , <br /> - Compliance reguires certification by the air handler unit manufacturer that the air handler e closure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. , <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ' <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 5/30/2017 1 44 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br /> � <br /> I <br />