17-18616
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18616
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:46:36 AM
Creation date
5/2/2018 6:46:34 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVEARDO
Building Department - Doc Type
Permit
Permit #
17-18616
Building Department - Name
LENNAR HOMES LLC
Address
36060 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, ; <br /> ' � ' • I <br /> FORM R405-2014 <br /> I <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTlON <br /> � Florida Department of Business and Professional Regulation - Residential Performance Method <br /> - , , <br /> Froject Name: 1871 sf ADS elev B • Builder Name: Lennar Homes � �', <br /> street: 36060 Stable Wilk Avenue� Permi�off�e: City of Zephyrhills ! <br /> City,State,Zip: ,FL, Permit Number � <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa ' County� Pasco(Florida Climate Zone 2) � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2361.0 sqft.) Insulation Area ' I <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1152.00 ft2 � <br /> b.Concrete Block-Int Insul,Exterior R=4.1 846.44 ft� , <br /> 3. Number of units,if multiple family 1_ c.Frame-Wood,Adjacent R=11.0 362.56 ftZ <br /> 4. Number of Bedroams 4 d.N/A R= ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1090.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1090.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1870 b.N/A R= ft� <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br />� 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 374 <br /> a. U-Factor Dbl,U=0.54 87.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 49.69 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ i <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency � <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 � <br /> SHGC: � � <br /> Area Weighted Average Overhang Depth: 1.369 ft. � <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems , <br /> 8. Floor Types (1870.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 780.00 ftZ b. Conservation features I <br /> b.Floor Over Other Space R=0.0 647.00 ft' None <br /> c.other(see details) R= 443.00 ftZ _ 15.Credits - Pstat <br /> Total Proposed Modified Loads: 61.79 PASS <br /> Glass/Floor Area. 0.091 <br /> Total Baseline Loads: 63.98 <br /> I <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'S�$T.q?':'�. . <br /> O � , <br /> � � <br /> this calculation are in compliance with the Flonda Energy specifications covered by this " ,=�;�, �'3r,�, <br /> Code. calculation indicates compliance r,J�.lf,;''l' '__;;;` "� � <br /> ,{/,� with the Florida Ener Code. h+ ,Ir;,rr�'"'�::�'�"�,�"��;��C9 � <br /> �aV� WL 9Y �, � '�,;;�, i <br /> PREPARED BY' r1 ��� Before construction is completed w , � � i <br /> DATE: this building will be inspected for �����'..:• � � i <br /> ��I: <br /> compliance with Section 553.908 ,�'�� � : � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ?",�, �� <br /> with the Florida Energy Code. � ��D W:E`�' <br /> OWNER/AGENT: BUILDING OF ICIAL. ' <br /> DATE: DATE: ' '' <br /> - Compliance requires certification by the�air handler unit manufacturer that the air handler e cl ure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 5/30/2017 1�44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.