Laserfiche WebLink
�. 1 � <br /> FORM R405-2014 , <br />� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2386A sf ADS Builder Name. Lennar Homes <br /> street: 36041 Stable Wilk Avenue Permit ot�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Pertnit Number <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa � County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1118.00 ftz <br /> 3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ftZ <br /> 4 Number of Bedrooms 5 d.N/A R= ft' <br /> 10.Ceiling Types (1272.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1120.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 2389 b.Knee Wall(Vented) R=30.0 152.�0 ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft= <br /> 11 Ducts R ftZ <br /> 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br /> a. 11-Factor Dbl,U=0.54 96.00 ft2 <br /> SHGC: SHGC=0.31 � <br /> b. U-Factor Dbl,U=0.56 38.68 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ � a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.397 ft. <br /> Area Weighted Average SHGC: 0.3�5 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2389.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft= b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ft' None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.070 Total Proposed Modified Loads. 70.83 PASS <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ����T`�g?. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � '�,�'��t7,�,,,, <br /> Code. calculation indicates compliance � ���r„l�;'� ,._,��.�`.y�, <br /> `� 1 r, t11�7 ` �"t�:�-•• a\` <br /> with the Florida Energy Code. ,� �u..,;:.:;,t��,,,,, .O. <br /> PREPARED BY. �aV� ����� Before construction is completed w� �;, � <br /> ��',.:, � • � <br /> DATE: this building will be inspected for �. 1,,;��;, :� . <br /> compliance with Section 553.908 .* �'°:� � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. t,�; ,, ����.. � <br /> with the Florida Energy Code. �'flT�.WE'� <br />' OWNER/AGENT: BUILDING OFFICIAL: -� <br /> DATE. DATE: � <br /> - Compliance requires certiFcation by the air handler unit manufacturer that the air handler enclosure qualifies as <br />� certified factory-sealed in accordance with R403.2.2.1. • <br />� -Com liance re uires an Air Barrier and Insulation Ins ection Checklist in accordance with R402.4.1.1 and an envelo e leaka e <br /> i P q P • P 9 i <br />, test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than.0.030 Qn for whole house. � <br /> 6/12/2017 3:02 PM EnergyGaugeO USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 5 <br />