Laserfiche WebLink
, , . <br />� , , ` <br /> FORM R405-2014 ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> ' Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2386A sf ADS Builder Name: Lennar Homes <br /> street: 36041 Stable Willc Avenue Perr„�t ot�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1118.00 ft2 <br /> 3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft' <br /> 4. Number af Bedrooms 5 d.N/A R= ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1120.00 ft <br /> 6. Conditioned floor area above grade(ft2) 2389 b.Knee Wall(Vented) R=30.0 152.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft� <br /> 11 Ducts R ftZ <br /> 7 Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br /> _ a. U-Factor: Dbl,U=0.54 96.00 ftz <br /> SHGC: SHGC=0.31 <br /> b.��U-Factor Dbl,U=0.56 38.68 ft' 12.Cooling systems kBtu/hr Efficiency <br /> " ' SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor• Dbl,U=0.56 33.33 ft' <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.397 ft. <br /> Area Weighted Average SHGC: �.305 14 Hot water systems <br /> 8. FloorTypes (2389.0 sqft.) Insulation Area a.Electric Cap:40gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft� b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ftZ None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area. 0.070 Total Proposed Modified Loads. 70.83 pASS <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0����53��� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ,�i,� � _.��, p�, <br /> Code. calculation indicates compliance �'�ri„ "'�, �°�`.��t�� <br /> /,� /' with the Florida Energy Code. �+ <rrror��'r;`:`�:=;.;'.�+�,ti�O. <br /> PREPARED BY: �aV� �GUL{'l�VL Before construction is completed � ;, � �""�" � <br /> 5 <br /> DATE. this building will be inspected for �. . ""�`�' " �+� <br /> '.��'. <br /> compliance with"Section 553.908 * 'Q ,� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. e�^11, ����- � <br /> with the Florida Energy Code. ' GOl)WE'� <br /> OWNER/AGENT: BUILDING O CI L.� ' <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope-leakage <br /> `test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 6/12/2017 3:02 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />