Laserfiche WebLink
J , • ' _ <br /> • FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name. 2575 B sf ADS Buiider Name: Lennar Homes <br /> street: � 36046 Stable Wilk Avenue Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.8 sqft.) Insulation Area <br /> a.Frame-Wood,Exterior R=11.0 1273.30 ftz <br /> 2. Single family or multiple family Single-family b.Concrete Block-Int Insul, Exterior R=4.1 988.00 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4 Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11 Ducts R ft2 <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> i a. U-Factor Dbl,U=0.54 71.25 ftZ b.Sup: Attic, Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor� Dbl,U=0.56 71.00 ftZ �Z•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor� Dbl,U=0.56 33.33 ft2 <br /> - SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br />� Area Weighted Average SHGC: 0.300 14 Hot water systems <br />� 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1049.00 ft� None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area. 0.068 Total Proposed Modified Loads. 74.45 PASS <br /> Total Baseline Loads. 74 36 <br /> I hereby certify that the plans and specifications covered by Review of the plans and fl�•�ST�qT�. •. <br /> this calculation are in compliance with the Florida Energy specifications covered by this �, ;_ '" ,_�;� C3�,, . <br /> Code. calculation indicates compliance ��::,,f�;`?� '_=.�'r��•,��/try <br /> ' �`M,s.�fFi7f�bpi 4='::.�`��k�, `10 <br /> /. with the Florida Energy Code. �, , .,., �<<s�„m � . <br /> PREPARED BY: �a�e �����'c - Before construction is completed ru �• " � <br /> this buildin will be ins ected for � �}k�' � � <br /> DATE. 9 P t9 �_"' •�* <br /> >,<J�: .,� , <br /> compliance with Section 553.908 �, , � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. t �' . . ��� <br /> with the Florida Energy Code. � �D WE`� <br /> OWNER/AGENT: BUILDING OFFIC�AL: <br /> DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> - certified factory-se�led in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 6/13/2017 2:44 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> � <br /> � <br />