Laserfiche WebLink
, <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name. 2575 B sf ADS Builder Name: Lennar Homes <br /> straet: 36046 Stable Wilk Avenue Pem,it ot�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Pertnit Number <br /> Owner Lennar homes� Jurisdiction:611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1273.30 ft' ' <br /> b.Concrete Block-Int Insul,Exterior R=4.1 988.00 ft� <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft� <br /> 4 Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2582 b.N/A R= ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' , <br /> 11 Ducts R ftZ <br /> 7 Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> a. U-Factor: Dbl,U=0.54 71.25 ft' b.Sup: Attic, Ret:2nd Floor,AH:2nd Floor 6 258.4 <br />, SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 71.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14 Hot water systems <br /> 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1�93.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1049.00 ft' None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area. 0.068 Total Proposed Modified Loads. 74.45 pASS <br /> Total Baseline Loads. 74.36 <br /> I hereby certify that the plans and specifications covered by Review of the plans and fl�'4��T��� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this °4� , ,� '��+ 0,�,. <br /> Code. calculation indicates compliance ��n,l�''4�; _..��,�,„`� <br /> with the Florida Ener Code. ' � �n�l�f�? ��=;�:��'`�``. „ O � <br /> �a�e �Col�cl� gy ::s a:�;,,:+�. is <br />� PREPARED BY: Before construction is completed w� 1�� ,� <br /> DATE: this building will be inspected for �:, ;-�!�j ��, <br /> is <br /> compliance with Section 553.908 ,� �'� � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �,�,. " � <br /> �. <br /> with the Florida Energy Code. � �bD�{�yE;`,� <br /> OWNER/AGENT. BUILDING OFFI L. <br /> DATE: DATE. ' <br /> - Compliance requires certiFcation by the air handler unit manufacturer that the air handler enclosure qualifies as - <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.7.2. <br /> 6/13/2017 2:44 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , <br />