Laserfiche WebLink
, ' � ' <br /> Pro ect Summa Job: 3711A sf ADS <br /> � � Date: 6/13/2017 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> e s � • <br /> For: Lennar Homes <br /> N otes. <br /> i - e e s <br /> Weather: Tampa InternationalAP, FL, US , <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F I <br /> Inside db 70 °F Inside db 75 °F <br /> I Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16810 Btuh Structure 17381 Btuh <br /> Ducts 2143 Btuh Ducts 2459 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh � <br /> Equipment load 18954 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19840 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2038 Btuh <br /> Ducts 435 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftZ) 2002 2002 Equipment latent load 2473 Btuh <br /> Volume(ft') 16014 16014 <br /> Air changes/hour 0.28 0.14 Equipment Total Load (Sen+Lat) 22312 Btuh <br /> Equiv.AVF (cfm) 74 39 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary ' <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024-230-21 Cond 14HPX-024230-21 <br /> AHRI ref 10258598 Coil CBA27UHE-024230*++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.042 cfm/Btuh Air flow factor 0.040 cfm/Btuh <br /> Static pressure 0 irrH2O Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point=28°F <br /> Backup: - <br /> Input= 6 kW, Output= 20366 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> � wri htsoftn - z017-Jun-13 09:28:17 <br /> �A g Right-Sulte�Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...th CBA27UHE AH's\3711Asf ADS drawn 2+2tons.rup Calc=MJS Front Doorfaces: S <br />