V <br /> f Ji <br /> Manual S Corv�pliance Report Job: 3711AsfADS <br /> Date: 6/13/2017 <br /> lowerf�oor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' a - • a <br /> For• Lennar Homes - <br /> • • e • e <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 20060 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB� 77.3°F Latent gain: 2081 Btuh Entering coil WB� 62.9°F <br /> Indoor design DB: 75.O�F Total gain: 22142 Btuh <br /> Indoor RH� 50% Estimated airflow� 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR <br /> Actual airflow� 800 cfm <br />' Sensible capacity: 21420 Btuh 107% of load <br /> Latent capacity� 3780 Btuh 182% of load <br /> Total capacity� 25200 Btuh 114% of load SHR. 85% <br /> • e • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss 25546 Btuh Entering coil DB 69.6°F <br /> Indoor design DB• 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230'`++TDR <br /> Actual airtlow: 800 cfm <br /> Output capacity� 21800 Btuh 85% of load Capacity balance: 36 °F <br /> Supplemental heat required: 3746 Btuh Economic balance: -99 °F <br /> � <br /> Backup equipment type: Elec strip <br /> Manufacturer Model: <br /> Actual airflow� 800 cfm <br /> Output capacity' 7.9 kW 105% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S , <br /> .�, wri htsoft'� 2017-Jun-13 09:28:17 <br /> �� 9 Right-SuOe�Universal 2017 17.0.23 RSU05714 Page 1 <br /> .th CBA27UHE AH's13711Asf ADS drawn 2+2tons.rup Calc=MJS Front Doorfaces: S <br />