My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
885-04 Rucks Future Land Use and Rezoning
Zephyrhills
>
Administration
>
City Clerk
>
Vault Files
>
ORDINANCES
>
2000-2009
>
885-04 Rucks Future Land Use and Rezoning
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2018 2:52:56 PM
Creation date
6/5/2018 2:52:55 PM
Metadata
Fields
Template:
Administration
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OR BK 6162 PG 58 <br /> 3 of $ <br /> c. At the intersection of Chancy Road and Residential Drive 3: <br /> (1) Construct a northbound combined left and right turn lane. <br /> d. At,the intersection of Chancey Road and Residential Drive 4: <br /> (1) Construct a northbound and southbound combined left and right turn lane <br /> and through lane. <br /> e. At the intersection of S.R. 39 and Community Drive 1: <br /> (1) Construct a southbound left, westbound left, and right turn lanes, and <br /> signalize when warranted by MUTCD. <br /> f. At the intersection of Chancey Road and Community Drive 2: <br /> (1) Construct northbound and southbound left and right turn lanes and through <br /> lane; <br /> (2) Construct eastbound and westbound left turn lanes, and signalize when <br /> warranted by MUTCD. <br /> g. At the intersection of Chancey Road and Community Drive 3: <br /> (1) Construct northbound and southbound left and right turn lanes and through <br /> lane. <br /> 8. The traffic study submitted by the developer assumes mixed use development. Prior to <br /> approval of the final plat, the developer shall bond or construct any off-site improvements <br /> identified herein. Offsite improvements include: <br /> a. Signalization of the U.S. 301 and 39 intersection when warranted by MUTCD. <br /> 9. Stormwater management and drainage plans, including construction of roads and lift <br /> stations shall be at the 25 year flood elevation and shall be designed in accordance with <br /> Southwest Florida Water Management District (SWFWMD) requirements for open drainage <br /> basins. The developer shall submit a lot grading plan. <br /> 10. The City of Zephyrhills shall provide water and/or wastewater service to the project, a <br /> master utility plan for the project shall be submitted to the Utilities Director for review and <br /> approval prior to the construction plan approval and the developer shall construct all water and <br /> wastewater facilities within the development to current City standards. <br /> 11. Development shall be in accordance with the Preliminary Development Plan submitted to <br /> the City dated May 5, 2004. The approved uses and conditions of approval are as follows: <br /> a. Maximum of 354 single family (lot layout may be modified based on final <br /> engineering design); 126 Town-home Units; and 270,000 Square Feet of <br /> Commercial Uses. <br /> b. Typical Minimum Lot Sizes and side setbacks shall be: <br /> 45 ft. x 120 ft. with 6 ft. side setbacks <br /> 50 ft. x 115 ft. with 7.5 ft. side setbacks <br /> 60 ft. x 115 ft. with 7.5 ft. side setbacks <br /> c. Front and Rear Setbacks: <br /> Front—20 ft. <br /> Rear— 15 ft. <br /> d. A uniform mailbox and post design shall be provided throughout the community. <br /> e. A Street Tree Plan shall be included in the Final Development Plan. <br />
The URL can be used to link to this page
Your browser does not support the video tag.