My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
405 Annexation Ordinance – Halterman
Zephyrhills
>
Administration
>
City Clerk
>
Vault Files
>
ORDINANCES
>
1980-1989
>
405 Annexation Ordinance – Halterman
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2018 9:53:42 AM
Creation date
7/19/2018 9:53:42 AM
Metadata
Fields
Template:
Administration
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> '\.,cP*�►eiij�, ZEPHYRHILLS FIRE DEPARTMENT <br /> Zephyrhills Florida 34248 <br /> • 1 • <br /> .2. 700 6th Avenue (813) 782-8184 <br /> 44‘1,0'' September 15 , 1986 <br /> To: Nick Nichols - City Planner, Zephyrhills <br /> Fire Chief • <br /> William T. Fenton Re : Arleigh A. and Diana Halterman Property - Proposed Annexation of <br /> Assistant Chief Multiple Structures - Fire Code Violations <br /> Robert Hartwig <br /> General Comments <br /> Based on the ZFD Inspection of the Haltermans' Properties on friday <br /> September 12, 1986 at approximately 9:00 a.m, , the following was determined <br /> in viewing the cement block building that is part of the Pole Barn con- <br /> . struction and the Pole Barn itself. <br /> The two buildings mentioned above are not in compliance with the Fire <br /> • • Codes. The basic fire code requirements come under NFPA 101 (Life Safety) <br /> and the Standard Building Code in Chapter 4 (mixed occupancy), and Chapter 7 <br /> • . (Fire Separation and Compartmentation. ) <br /> Zephyrhills Fire Department requirements within 30 days of annexation <br /> would- be that 'the following items shall be completed: <br /> 1. All existing leased/rented occupancies shall have a minimum of <br /> 1 hour fire rated compartmentation for light and ordinary hazards. <br /> 2. Any leased/rented area that is considered a high hazard area, such <br /> as auto repairs , spray painting, storage of hazardous materials, etc. <br /> shall have a 2 hour fire rated compartmentation. <br /> 3. Any penetration of rated' walls' shall be properly filled and fire- <br /> stopped. If there is penetration of rated walls by electric, the <br /> wires shall be in metal conduit. <br /> 4. Fire extinguishers shall be located in each leased/rented space with <br /> a minimum fire rating of 2A,'lOB:C. For leased/rented spaces that are <br /> a greater than ordinary hazard, they shall comply ,with NFPA 10_ (Port- <br /> able Fire Extinguishers. ) <br /> 5. Single-station smoke detectors (battery operated) shall be installed <br /> as follows : <br /> a) At least one smoke detector in each leased/rented unit. <br /> b) One detector in each dead storage area within the leased/rented sp. <br /> • c) In leased/rented spaces over 60.0 sq. ft. , one additional smoke ' <br /> detector shall be installed. for 'each 600 sq. ft.or portion. thereof <br /> 6. Any leased/rented space that is open to the public shall have a plasti <br /> exit sign with 6" letters over the exit . <br /> 7. Existing common bathrooms and. doors from one leased/rented area to <br /> another shall have doors with a minimum of a 20 minute fire rating, <br /> be set in metal frames , and have automatic door closers. <br />
The URL can be used to link to this page
Your browser does not support the video tag.