Laserfiche WebLink
a - . . , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Perforrriance Method <br /> Project Name: 2600B sf ADS Builder Name: LENNAR HOMES <br /> street: 6527 Paden Wheel Street Permit o�tice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number G�j,Z� <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? � Yes 10.Ceiling Types (2599.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2599.00 ft <br /> 6. Conditioned floor area above grade(ft2)' 2599 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft� , <br /> 11 Ducts R ftz <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8 <br /> a. U-Factor: Dbl,U=0.54 141.68 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 • 72.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 48.00 ft' <br /> SHGC: SHGC=0.32 13.Heating.systems kBtu/hr Efficiency <br /> d. U-Factor other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems <br /> 8. Floor Types (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 82.41 pASS <br /> Glass/Floor Area: 0 115 <br /> Total Baseline Loads: 82.65 <br /> � <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'t?�ST.��.� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � , ,�� ��_�.� t7y,t,� <br /> Code. , calculation indicates compliance �'�>r;,;'`r� �_='.•��„�. � <br /> with the Florida Ener Code. �. Irr�r{�'%:`�:,;:_�:�'°�"'P,ti O. <br /> /. 9Y � a��;,::s�.. �.. <br /> PREPARED BY: '�ave ����V` Before construction is completed �. •� ►� <br /> �: �7.. �__. t'7 <br /> DATE. this building will be,inspected for Lry:g, i,,� � : <br /> compliance with Section 553.908 *� '� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. t�,� � ����� <br /> .with the Florida Energy Code. D yyE� <br /> , <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE: � ` � DATE. <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accord nce with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. ' <br /> 6/13/2017 1�19 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />