Laserfiche WebLink
.� - � • . . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600B sf ADS Builder Name: LENNAR HOMES <br /> street: 6527 Paden Wheel Street Permit office: City of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4 Number of Bedroams 4 d.N/A R= ft'' <br /> 5. Is this a worst case? Yes �0.Ceiling Types (2599.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 2599.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2599 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft') 0 c.N/A R= ftZ <br /> 11 Ducts R ft2 <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8 <br /> a. U-Factor: Dbl,U=0.54 141.68 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 72.00 ft�� 12•Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 48.00 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2599.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ft� 15.Credits Pstat <br /> Glass/Floor Area: 0 115 Total Proposed Modified Loads. 82.41 pASS <br /> Total Baseline Loads: 82.65 ' <br /> � <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'�$�'<q�•.� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �M1r ,f � ��� {��,, . <br /> Code. calculation indicates compliance v}'��,,,��'�? -' ;�ry� <br /> !� :rtrirrt`�';,,'o;,::a4r�`+X. ti O. <br /> �ave �Gal�rcl� �✓ith the Florida Energy Code. �, . �„"�,�,,,, � <br /> PREPARED BY' Before construction is completed •w � <br /> � ���;�.�. cs <br /> DATE: this building will be inspected for Lry ��ry;��:�t. . � <br /> compliance with Section 553.908 .��"� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �',�, ; � ���.µ <br /> with the Florida Energy Code. ��I�y1'fi`�' <br /> . <br /> OWNER/AGENT. BUILDING O FICIAL: <br /> DATE: DATE: ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as - <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 6/13/2017 1•19 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br /> . � <br />