My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18704
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2018 9:02:45 AM
Creation date
7/27/2018 9:02:43 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18704
Building Department - Name
LENNAR HOMES INC
Address
36029 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:._ } � . '��.'. <br /> .. .;.;.-�-. <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOt� BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name. 2575A sf ADS 2017 Builder Name: Lennar Homes � <br /> screet: 36029 Stable Wilk Avenue PerTr,it o�ice: City of Ze hyrhills <br /> City,State,Zip: ,FL, � Permit Number � ��Ot� <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ <br /> 4 Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30:0 1491.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2584 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11 Ducts R ft2 <br /> 7 Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor� Dbl,U=�.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=�.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtulhr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14 Hot water systems <br /> 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 1051.00 ft� None <br /> ' c.other(see details) R= 440.00 ft2 1�5.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.43 pASS <br /> Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'T��:�T.q�.� ": <br /> this calculation are in compliance with the Florida Energy specifications covered by this �. ,G�� � p�,. <br /> Code. calculation indicates compliance r��.,�� r'r r =;;-��i: �+. <br /> 4 ..=. �t���� <br /> �a�e �/��G/. with the Florida Energy Code. �+ �rrr���%��.�:=:=>°�;��y��t, O <br /> PREPARED BY' W� �� Before construction is completed �� -F ' '+ � <br /> DATE. this buildin will be ins ected for � "°��"` .� � <br /> 9 P t7. _ ����;�- :� <br /> corripliance with Section 553.908 ,. �'-�'� „ <br /> Florida Statutes. .t � <br /> I hereby certify that this building, as designed, is in compliance - �� ��, <br /> with the Florida Energy Code. 4D�{�y�'�' <br /> OWNER/AGENT: BUILDING OFFIC AL. <br /> DATE: � f ' � DATE: ' - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handlerenclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.,1. " <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in.accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6:48 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.