My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18704
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2018 9:02:45 AM
Creation date
7/27/2018 9:02:43 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18704
Building Department - Name
LENNAR HOMES INC
Address
36029 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2Q14 - <br /> FLt�RIDA ENERGY EFFICIENCY CODE FOR"BUILDING CCANSTRUCTION <br /> Flarida Department-of Business and ProfessionaE Regulation - Residential Perfarmance Methocf <br /> Praject Name: 2575A sf ADS 2017 - Buiider Name: Lennar Fiames <br /> street: 36029 Stable Wi1k Avenue perr„�t o�ice: City of Zephyrhills <br /> Gity;State,Zip: ,F!�, Permit Number <br /> Owner� Lennar Homes Jurisdiction: 611.600 <br /> Design Location: FL,Tampa County� Pasco(Floeida ClimaYe 2ane 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or mulfiple famify Single-#amily a.Frame-Wood,E�cteriar R=11 A 1264.Q4 ft2 <br /> b.Concrete Block-Int Insu�,E�erior R=4 1 996.67 ft <br /> 3. Number of units,.if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4. Number af 8edroams 4 d.NiA R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area z <br /> a.Under Attic(Vented) R=30.0 1491.00 ft <br /> 6. Gondit`toned flaor area above grade{ftz} 2584 b.NIA R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11 Ducts R ft� <br /> 7 Windows(175.8 sqft.} Descriptian Area a.Sup:Aftic,Ret:2nd Floar,AH:2nd Floor 6 258.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ft' b.Sup: Attic, Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=Q.31 <br /> b. U-Factflr Dbl,U=0.56 71.4d ft2 12.CooEing systems kBfuthr Efficiency _ <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor DbI,U=0.56 33.33 ft2 <br /> SHGC: SNGC=0.32 13.Heating systems kBtu/hr Eificiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 17,5 HSPF:8.50 <br /> SHGG: b.Electric F1eat Pttmp 21.8 HSPF:8.5d <br /> Area Weighted Average Overhang Depth. 1 190 ft. <br /> Area Weighted Average SHGC: Q.3p0 14 Hot water systems <br /> 8. FloorTypes (2584.6 sqft.} Insulakion Area a.E]ectric Cap:44 gallons <br /> EF'0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft� b. Conservation features <br /> b.Flaor Over Other Space R=d.O i 051.a0 ft�an� <br /> c.other(see details) R= 440.00 ft2 15.Credits Pstat <br /> Glass/Floor Area. 0.068 <br /> Total Prop�sed Madified Laads. 74 43 pAS� <br /> Total Baseline Loads. 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the p{ans and �,�'L��'T�?.�„ .. <br /> r�_. <br /> this calculation are in comptiance with the Fiorida Energy specifications covered by this *� � _ �,� taM,�, . <br /> . <br /> Code. calculation indicates compliance r,�'�,rrr,,�` '"�=`;;�',�•'�. •�'� <br /> with the Fforida Energy Code. h�au,�':'�f:;:$�'�'`::�;�*:��O_ <br /> ���c �#Gr�I�LI� ,�,y�. � <br /> PREPARED BY' f Before construction is completed � W '" <br /> �'. ..� ..=i_ .... . t7 <br /> DATE: this building will be inspected for �:. j. : :�; . <br /> , �� . <br /> comp[iance with Section 553.908 �. � � :� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. },�,� ,. ���, <br /> with the Florida Energy Code. 4L��;`T¢ <br /> iOWNER/AGENT: BUILDING OFFICIAL: <br /> DATE. DATE. � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> cerEifiec!factory-sealed in accardance with R403.2.2.9. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.i.2. <br /> - Gompliance with a propased duct leakage Qn requires a Duct Leakage Test Repart confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> ' 71&12t117 8:48 AM EnergyGauget�3 USA-FlaRes20i4 Section R405.4.9 Compiiant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.