My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18704
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2018 9:02:45 AM
Creation date
7/27/2018 9:02:43 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18704
Building Department - Name
LENNAR HOMES INC
Address
36029 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Jo6: 2575A sf ADS 2017 <br /> Building Analysis Date: 716/2017 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - o s . - <br /> For: Lennar Homes <br /> 6 - • e • o <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> • <br /> Component. Btuh/ft2 Btuh % of load <br /> Walls 3.8 4219 32.8 �� <br /> Glazing 30.2 2608 20.3 <br /> Doors 0 0 0 Wa" <br /> Ceilings 1.3 1870 14.6 <br /> F�OOfS 0 0 0 nfl�tration <br /> Infiltration 19 2307 17.9 <br /> D ucts 1846 14.4 - <br />� Piping 0 0 <br /> Humidification 0 0 Ceilings <br /> Ventilation Q Q Glazing <br /> Adjustments 0 <br /> Total 12850 100.0 <br /> � e • • <br /> Component Btuh/ftz Btuh % of load <br /> Walls 2.7 3046 15.9 Walls <br /> Glazing . 52.7 4554 23.7 <br /> Doofs 0 0 0 Intemal Gains <br /> Ceilings 1.7 2586 13.5 <br /> Floors 0 0 0 <br /> Infiltration 0.4 514 2.7 1 <br /> Ducts 2137 11.1 Glazing . <br /> Ventilation 0 0 <br /> Internal gains 6380 33.2 <br /> Blower 0 0 <br /> Adjustments 0 oucts <br /> Total 19277 100.0 Ceilings Infiltration <br /> Latent Cooling Load=2645 Btuh <br /> Overall U-value= 0.083 Btuh/ftz-°F <br /> Data entries checked. <br /> �, wri htsoft` 2017-Ju1-06 06:32:07 <br /> �� 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...dh CBA27UHE AH's\2575A1 sfADS drawn 1.5-2.rup Calc=MJB Front Doorfaces: 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.