Laserfiche WebLink
, . � <br /> Pro ect Summa1�� Job: 2575A sf ADS 2017 <br /> J . '7 Date: 7/6/2017 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> � m - • � <br /> For: Lennar Homes <br /> Notes. <br /> S - • • • . <br /> Weather• Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F , <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib • <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 14848 Btuh Structure 9681 Btuh <br /> Ducts 1400 Btuh Ducts 1655 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Eqwpment load 16249 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 11336 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> _ Fireplaces 0 Structure 939 Btuh <br /> Ducts 294 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftZ) 1093 1093 Equipment latent load 1233 Btuh <br /> Volume(ft') 9638 9638 <br /> Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12569 Btuh <br /> Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES ' <br /> Model 14HPX-018-230-21 Cond 14HPX-018-230-21 <br /> AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR <br /> AHRI ref 10258596 <br /> Efficiency ' _ 8.5 HSPF Efficiency 13.0 EER, 16 SEER <br /> Heating input Sensible cooling 16915 Btuh <br /> Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh <br /> Temperature rise 26 °F Total cooling 19900 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.90 <br /> � Capacity balance_point= 31 °F <br /> Backup: <br /> Input=4 kW, Output= 15295 Btuh, 100 AFUE � <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> � '� wrightsoft'° Right-Suite�Universal 2017 17.0.23 RSU05714 2017-:1uF06 06:32:07 <br /> ,�� ' Page 1 <br /> ...ith CBA27UHE AH's12575A1 sfADS drawn 1.S2.rup Calc=MJ8 Front Doorfaces: S <br />